Permit: T19CM03802
Permit Details
Status:
Expired
Type:
Residential Building - One or Two Family
Address:
7351 E NICARAGUA DR
Address NEW:
7351 E NICARAGUA DR
Apply Date:
05/29/2019
Applicant:
Description:
EXTEND BEDROOM
Permit Reviews
Permit Number - T19CM03802
Permit Status: Expired
Permit Description: EXTEND BEDROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/29/2019 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 05/29/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM03802
Permit Status: Expired
Permit Description: EXTEND BEDROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/29/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T19CM03802
Permite Description: EXTEND BEDROOM
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/04/2022 | COT - RSME - Mechanical Final | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | RSBU - Building Final | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | COT - RSEL - Electrical Final | N/A | Canceled | Inspection Canceled |
| 11/07/2022 | COT - RSPL - Plumbing Final | N/A | Canceled | Inspection Canceled |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM03802
Permit Description: EXTEND BEDROOM
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/19/2019 | COT - RSPL - Rough Soil | Passed | {Activity date: 08/19/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/16/2019; Status: Denied; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - plans are to be on site for inspection, remove mill tape from fittings.} | |
| 08/21/2019 | COT - RSBU - Preslab | Passed | {Activity date: 08/21/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - } | |
| 08/21/2019 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 08/21/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - } | |
| 09/20/2019 | COT - RSBU - Roof Nailing | Passed | {Activity date: 09/20/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VFLORES1 - } | |
| 09/20/2019 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 09/20/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VFLORES1 - } | |
| 10/23/2019 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 10/23/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/08/2019; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Approved plans are to be on site. Provide anchor bolts at exterior bottom plate where needed. DWV not on test. Water piping at shower not complete. All wood in contact with concrete to be pressure-treated. Existing wiring being abandoned to be removed. Mechanical to be on plans, no mechanical at this time with the exception of exhaust fan.} | |
| 10/23/2019 | COT - LCBU - Framing | Passed | {Activity date: 10/23/2019; Status: Approved; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/08/2019; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Approved plans are to be on site. Provide anchor bolts at exterior bottom plate where needed. DWV not on test. Water piping at shower not complete. All wood in contact with concrete to be pressure-treated. Existing wiring being abandoned to be removed. Mechanical to be on plans, no mechanical at this time with the exception of exhaust fan.} ; {Activity date: 09/20/2019; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VFLORES1 - } |