Permit: T19CM03629
Permit Details
Status:
Expired
Type:
Residential Building - One or Two Family
Address:
9468 S DESERT FAUNA LP
Address NEW:
9468 S DESERT FAUNA LP
Apply Date:
05/21/2019
Applicant:
Kimberly York
Description:
SFR KB146517 T17-M0027
Outstanding Activity Conditions
Permit Number - T19CM03629
Permit Status: Expired
Permit Description: SFR KB146517 T17-M0027
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 05/21/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 05/21/2019 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 05/21/2019 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 05/21/2019 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM03629
Permit Description: SFR KB146517 T17-M0027
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/24/2019 | COT - RSPL - Yard Water Line | Passed | {Activity date: 05/24/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - } | |
| 05/24/2019 | COT - RSPL - Sewer | Passed | {Activity date: 05/24/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - } | |
| 05/24/2019 | COT - RSPL - Rough Soil | Passed | {Activity date: 05/24/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Ok to backfill } |
|
| 06/03/2019 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 06/03/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 06/03/2019 | COT - RSBU - Preslab | Passed | {Activity date: 06/03/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 06/03/2019 | COT - RSEL - Electrical Underground | Passed | {Activity date: 06/03/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 06/03/2019 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 06/03/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 06/18/2019 | COT - RSBU - Roof Nailing | Passed | {Activity date: 06/18/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 06/18/2019 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 06/18/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 07/03/2019 | COT - LCBU - Framing | Passed | {Activity date: 07/03/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 07/03/2019 | RSME - Mechanical Progress | Passed | {Activity date: 07/03/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 07/05/2019 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 07/05/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VFLORES1 - All corrections have been made ok to proceed.} ; {Activity date: 07/03/2019; Status: Denied; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Install nail plates where needed. Provide DWV test on plumbing top out.} | |
| 07/05/2019 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 07/05/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VFLORES1 - All corrections have been made ok to proceed.} ; {Activity date: 07/03/2019; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 07/16/2019 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 07/16/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - CODE ECO} | |
| 07/16/2019 | COT - RSEL - Construction Power | Passed | {Activity date: 07/16/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Clear TEP (ECO).} | |
| 07/24/2019 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 07/24/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 08/28/2019 | COT - BULD - SWG Clearance | Passed | {Activity date: 08/28/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 08/28/2019 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 08/28/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Clear Southwest Gas.} ; {Activity date: 07/03/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 09/11/2019 | COT - RSME - Mechanical Final | Passed | {Activity date: 09/11/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 09/11/2019 | RSBU - Building Final | Passed | {Activity date: 09/11/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 09/11/2019 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 09/11/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 09/11/2019 | COT - RSPL - Plumbing Final | Passed | {Activity date: 09/11/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 09/11/2019 | COT - RSEL - Electrical Final | Passed | {Activity date: 09/11/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } |