Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/01/2019 | TEP CLEARANCE - PM | MHASSAN | Approved | CODE RECN |
05/01/2019 | ELECTRIC - FINAL | MHASSAN | Approved | |
05/01/2019 | ELECTRIC - RECONNECT | MHASSAN | Approved | OK to clear electric RECN |
05/01/2019 | ELECTRIC - RECONNECT | MHASSAN | Approved | exterior receptacle for dryer needs to be set up for an exterior location with a weatherproof cover. An additional 50 amp receptacle by panel also needs to be set up for an exterior location with a weatherproof cover. Romex going down the exterior wall to the panel needs to in conduit. Smoke alarm needed outside of sleeping area. |