Permit: T19CM02763
Permit Details
Apply Date:
04/17/2019
Applicant:
Vance Goodman
Description:
NEW SHOWROOM AND SERVICE BAYS
Permit Reviews
Permit Number - T19CM02763
Permit Status: Expired
Permit Description: NEW SHOWROOM AND SERVICE BAYS
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/10/2020 | REVISION - - 2ND | 08/04/2020 | COMPLETED |
04/17/2019 | PLANS OK TO SUBMIT - COMM | 04/26/2019 | COMPLETED |
05/01/2019 | COMMERCIAL - NEW | 05/30/2019 | COMPLETED |
05/30/2019 | RESUBMITTAL | 08/08/2019 | COMPLETED |
08/04/2020 | REVISION - - 3RD | 08/27/2020 | COMPLETED |
11/15/2019 | REVISION - - 1ST | 11/15/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM02763
Permit Status: Expired
Permit Description: NEW SHOWROOM AND SERVICE BAYS
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/17/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Conditions
Permit Number - T19CM02763
Permit Status: Expired
Permit Description: NEW SHOWROOM AND SERVICE BAYS
Date | Description | Comments |
---|---|---|
05/14/2019 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) | |
05/14/2019 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) | |
05/14/2019 | SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. | |
05/14/2019 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. | |
05/14/2019 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. | |
05/14/2019 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
05/14/2019 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T19CM02763
Permite Description: NEW SHOWROOM AND SERVICE BAYS
Total Outstanding Inspections - 7
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/27/2019 | COT - HCBU - Exterior Clips/Sheathing | N/A | Canceled | {Activity date: 09/27/2019; Status: Not Applicable; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } |
08/27/2020 | COT - LCEL - Temporary Service | N/A | Canceled | {Activity date: 08/27/2020; Status: Not Applicable; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Not Applicable.} ; {Activity date: 10/23/2019; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Work incomplete.} |
11/07/2022 | COT - LCBU - Building Final | N/A | Canceled | Inspection Canceled |
11/07/2022 | ENGR Engineering Final | N/A | Canceled | Inspection Canceled |
11/07/2022 | COT - FCON - Sprinkler - Final | N/A | Canceled | Inspection Canceled |
11/07/2022 | COT - FCON - Fire - Final | N/A | Canceled | Inspection Canceled |
11/07/2022 | COT - LCBU - CofO | N/A | Canceled | Inspection Canceled |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM02763
Permit Description: NEW SHOWROOM AND SERVICE BAYS
Total Completed Inspections - 32
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/12/2019 | COT - LCPL - Sewer | Passed | {Activity date: 09/12/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 09/11/2019; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Provide test at fittings.} | |
09/17/2019 | COT - LCEL - Grounding/Bonding | Passed | {Activity date: 09/17/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } | |
10/02/2019 | COT - LCME - Mechanical Underground | Passed | {Activity date: 10/02/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } | |
10/23/2019 | COT - LCEL - Construction Power | Passed | {Activity date: 10/23/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } | |
11/12/2019 | COT - LCPL - Yard Water Line | Passed | {Activity date: 11/12/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/09/2019; Status: Partial Approval; Inspector: JCLAXTON; Comment: Entered by DMERANZ1 - } | |
12/17/2019 | COT - LCBU - Masonry Pregrout | Passed | {Activity date: 12/17/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - Last lift ok to grout. } ; {Activity date: 12/11/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Fourth lift complete.} ; {Activity date: 12/10/2019; Status: Partial Approval; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Third lift OK south section } ; {Activity date: 12/09/2019; Status: Not ready for Inspection; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - 1- Contractor called and cancelled the inspection request } ; {Activity date: 12/06/2019; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Second lift South Elevation ok for grout, from Grid Line (F-E.8)-(3.8- 10).} ; {Activity date: 12/04/2019; Status: Partial Approval; Inspector: MRAMBER; Comment: Entered by SFLORES2 - First lift South section OK} ; {Activity date: 11/25/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Top out grid line E and stem wall for service building.} ; {Activity date: 11/22/2019; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by DMERANZ1 - Grid line 10; top out from 8e to Southernmost expansion joint. To 25 feet North of 8e for 28 foot high section.} ; {Activity date: 11/21/2019; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Cancel by contractor} ; {Activity date: 11/20/2019; Status: Cancelled; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - per phone call with customer.} ; {Activity date: 11/19/2019; Status: Partial Approval; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Grid line E center wall 6th lift,grid line 10 north of E and west wall south of E to control joint ok 6th lift.} ; {Activity date: 11/15/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Sixth lift North of Southermost expansion joint.} ; {Activity date: 11/15/2019; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - RI canceled} ; {Activity date: 11/13/2019; Status: Cancelled; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - Canceled by contractor} ; {Activity date: 11/07/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - 3rd liftNorth of Southernmost control joints.} ; {Activity date: 11/06/2019; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Cancel by contractor} ; {Activity date: 11/04/2019; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by DMERANZ1 - 2 nd lift Gl e and gl 10 and gl 3.7 All ok to grout} ; {Activity date: 10/31/2019; Status: Partial Approval; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Gridline 10 north section 1st left and Gridline E from 10 to 4 OK first left.} ; {Activity date: 09/27/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Stemwall at main building except South wall.} ; {Activity date: 09/26/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Retaining walls.} ; {Activity date: 09/24/2019; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Canceled by contractor.} ; {Activity date: 09/18/2019; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Work incomplete at this time.} ; {Activity date: 09/17/2019; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Work incomplete at this time.} |
|
12/26/2019 | COT - LCBU - Preslab | Passed | {Activity date: 12/26/2019; Status: Approved; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/23/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - North half of service area to construction joint.} ; {Activity date: 10/11/2019; Status: Partial Approval; Inspector: JCLAXTON; Comment: Entered by DMERANZ1 - North of grid line E, ok to pour.} ; {Activity date: 09/27/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by ESTEVEN1 - BATTERY CONTAINMENT ROOM ONLY} ; {Activity date: 09/24/2019; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Canceled by contractor.} | |
02/18/2020 | COT - LCBU - Excavation/Rebar/Zoning | Passed | {Activity date: 02/18/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Four post bases for metal awnings on South side.} ; {Activity date: 11/13/2019; Status: Cancelled; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - Canceled by contractor} ; {Activity date: 09/26/2019; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 09/18/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Retaining wall and battery building.} ; {Activity date: 09/17/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - All building footings except South wall of service area.} ; {Activity date: 09/12/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Light poles.} | |
02/26/2020 | COT - LCPL - Plumbing Roof Drains | Passed | {Activity date: 02/26/2020; Status: Approved; Inspector: MRAMBER; Comment: Entered by SFLORES2 - } | |
05/01/2020 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 05/01/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - CODE ECO} | |
08/18/2020 | COT - LCME - Mechanical Above Ceiling | Passed | {Activity date: 08/18/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Approved} ; {Activity date: 08/14/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Partial. Showroom ceiling complete.} ; {Activity date: 08/03/2020; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - Partial approval for service writer area} ; {Activity date: 07/31/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Partial. Front radius ledge/ soffit area.} ; {Activity date: 07/30/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by JSCHNEI2 - Partial. Lower lid #105 service mgr’s office and #108 IT room.} ; {Activity date: 07/23/2020; Status: Partial Approval; Inspector: TTREBMULAK; Comment: Entered by RSALDAT1 - Partial. Soft lid above room 105, service managers office area.} ; {Activity date: 07/10/2020; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Partial, Mechanical Above Service Drive Thru Ok to proceed.} ; {Activity date: 05/18/2020; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - Partial approval delivery room only} ; {Activity date: 04/09/2020; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - RVI Partial. Restrooms, online sales office, finance office, retail parts and managers office, sales office and manager office, lounge area, café and mechanical closet.} ; {Activity date: 04/07/2020; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - } | |
08/18/2020 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 08/18/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Approved} ; {Activity date: 05/01/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - RVI Partial. Rooftop condensate & gas lines. } ; {Activity date: 04/09/2020; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - RVI Partial. Restrooms, online sales office, finance office, retail parts and managers office, sales office and manager office, lounge area, café and mechanical closet.} ; {Activity date: 04/07/2020; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - } ; {Activity date: 03/02/2020; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by SFLORES2 - Service area including Break room south of Gridline E is ok to one side drywall and exterior wall is ok to close, 100 psi on H/C water system DVW in walls good south of gridline E only} ; {Activity date: 02/26/2020; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by SFLORES2 - No work at this time.} |
|
08/18/2020 | COT - LCEL - Electrical Above Ceiling | Passed | {Activity date: 08/18/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Approved} ; {Activity date: 08/14/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Partial. Showroom ceiling complete.} ; {Activity date: 08/03/2020; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - Partial approval for service writer area} ; {Activity date: 07/31/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Partial. Front radius ledge/ soffit area.} ; {Activity date: 07/30/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by JSCHNEI2 - Partial. Lower lid #105 service mgr’s office and #108 IT room. } ; {Activity date: 07/23/2020; Status: Partial Approval; Inspector: TTREBMULAK; Comment: Entered by RSALDAT1 - Partial. Soft lid above room 105, service managers office area.} ; {Activity date: 07/10/2020; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Partial, Electrical above Service Drive Thru Ok to proceed.} ; {Activity date: 05/22/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Partial. Lights above outside service drive ceiling. } ; {Activity date: 05/18/2020; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - Partial approval delivery room only} ; {Activity date: 04/09/2020; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - RVI Partial. Restrooms, online sales office, finance office, retail parts and managers office, sales office and manager office, lounge area, café and mechanical closet.} ; {Activity date: 04/07/2020; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - } |
|
08/19/2020 | COT - LCBU - Sustainability | Passed | {Activity date: 08/19/2020; Status: Approved; Inspector: TTEMBULAK; Comment: Entered by JSCHNEI2 - Approved } ; {Activity date: 08/18/2020; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 09/27/2019; Status: Not Applicable; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } |
|
08/25/2020 | COT - LCME - Mechanical Final | Passed | {Activity date: 08/25/2020; Status: Approved; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - REVIEW OF AIR BALANCE REPORT COMPLETED} ; {Activity date: 08/19/2020; Status: Partial Approval; Inspector: TTEMBULAK; Comment: Entered by JSCHNEI2 - Partial. Approved upon air balance report.} ; {Activity date: 06/05/2019; Status: Prior to Final Inspectn; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - AIR BALANCE REPORT REQUIRED} | |
08/25/2020 | COT - FCON - Alarm - Final | Passed | {Activity date: 08/25/2020; Status: Approved; Inspector: jfordney; Comment: Entered by JFORDNE1 - } | |
08/25/2020 | COT - LCPL - Plumbing Final | Passed | {Activity date: 08/25/2020; Status: Approved; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - REVIEW OF WATER DISINFECTION REPORT COMPLETED} ; {Activity date: 08/18/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Partial. Approved, pending water disinfection report.} ; {Activity date: 06/05/2019; Status: Prior to Final Inspectn; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - WATER DISINFECTION REPORT REQUIRED} | |
08/26/2020 | COT - LCEL - Outdoor Lighting | Passed | {Activity date: 08/26/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by JSCHNEI2 - Approved} ; {Activity date: 08/25/2020; Status: Cancelled; Inspector: TTREMBULAK; Comment: Entered by JSCHNEI2 - Cancelled by contractor. Will reschedule} | |
08/26/2020 | COT - LCEL - Electrical Final | Passed | {Activity date: 08/26/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by JSCHNEI2 - Approved} ; {Activity date: 08/25/2020; Status: Cancelled; Inspector: TTREMBULAK; Comment: Entered by JSCHNEI2 - Cancelled by contractor. Will reschedule} | |
08/27/2020 | COT - LCPL - Gas Pressure Test | Passed | {Activity date: 08/27/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Approved, Clear Southwest Gas } |
|
08/27/2020 | COT - LCEL - Electrical Progress | Passed | {Activity date: 08/27/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Approved. } |
|
08/27/2020 | COT - LCEL - Electrical Intermediate | Passed | {Activity date: 08/27/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Approved.} ; {Activity date: 05/01/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - RVI Partial. Electric room, meter socket,and rooftop disconnects. Structure, water and gas grounding. **Clearance for TEP ECO ok } ; {Activity date: 04/09/2020; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - RVI Partial. Restrooms, online sales office, finance office, retail parts and managers office, sales office and manager office, lounge area, café and mechanical closet.} ; {Activity date: 04/07/2020; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - } ; {Activity date: 03/02/2020; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by SFLORES2 - service area including Break room south of Gridline E is ok to one side drywall and exterior wall is ok to close} |
|
08/27/2020 | COT - LCBU - Framing | Passed | {Activity date: 08/27/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Approved.} ; {Activity date: 04/09/2020; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - RVI Partial. Restrooms, online sales office, finance office, retail parts and managers office, sales office and manager office, lounge area, café and mechanical closet.} ; {Activity date: 04/07/2020; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - } ; {Activity date: 03/16/2020; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by SFLORES2 - Exterior wall north of Gridline E is OK for insulation} ; {Activity date: 03/05/2020; Status: Partial Approval; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - South of gridline E} | |
08/27/2020 | COT - LCEL - Electrical Underground | Passed | {Activity date: 08/27/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Approved.} ; {Activity date: 01/22/2020; Status: Partial Approval; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - 4 secondary conduits from transformer to new structure on east side only ok to back fill} ; {Activity date: 10/01/2019; Status: Partial Approval; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Electric below slab north of grid line E at showroom area ok.} ; {Activity date: 09/12/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Light poles.} ; {Activity date: 09/05/2019; Status: Partial Approval; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - OK feeders from switchgear to transformer., ok between light poles. } |
|
08/27/2020 | COT - LCBU - Exterior Clips/Sheathing | Passed | {Activity date: 08/27/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Approved.} ; {Activity date: 04/03/2020; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by VFLORES1 - Exterior soffits, except for large soffit at Service Drive.} ; {Activity date: 03/09/2020; Status: Partial Approval; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - Exterior framing OK at top 4 feet, OK to insulate.} ; {Activity date: 03/04/2020; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by SFLORES2 - Ok to install peel and seal over exterior sheathing} ; {Activity date: 02/19/2020; Status: Partial Approval; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - Top clip inspection on stud wall to roof attachment on west side as well as SW1 on west side} ; {Activity date: 02/06/2020; Status: Partial Approval; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - top clip inspection on stud wall to roof attachment on east,north, west and south sides} ; {Activity date: 02/04/2020; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Contractor rescheduled} | |
08/27/2020 | COT - LCPL - Plumbing Above Ceiling | Passed | {Activity date: 08/27/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Approved.} ; {Activity date: 04/09/2020; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - RVI Partial. Restrooms, online sales office, finance office, retail parts and managers office, sales office and manager office, lounge area, café and mechanical closet.} ; {Activity date: 04/07/2020; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - } | |
08/27/2020 | COT - LCPL - Rough Soil | Passed | {Activity date: 08/27/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Approved.} ; {Activity date: 03/26/2020; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by SFLORES2 - For grease interceptor leak check and install RVI} ; {Activity date: 10/11/2019; Status: Partial Approval; Inspector: JCLAXTON; Comment: Entered by DMERANZ1 - Grease trap line to mechanic sink, mop sink. Ok to cover} ; {Activity date: 10/09/2019; Status: Partial Approval; Inspector: JCLAXTON; Comment: Entered by DMERANZ1 - Outlet from grease trap G-F Inlet to grease trap 6-9.} ; {Activity date: 10/07/2019; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Two South bathrooms.} ; {Activity date: 09/05/2019; Status: Partial Approval; Inspector: MRAMBER; Comment: Entered by DMERANZ1 - OK at column line 6 and 7.8.} |
|
08/27/2020 | COT - LCME - Mechanical Intermediate | Passed | {Activity date: 08/27/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Approved.} ; {Activity date: 04/09/2020; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - RVI Partial. Restrooms, online sales office, finance office, retail parts and managers office, sales office and manager office, lounge area, café and mechanical closet.} ; {Activity date: 04/07/2020; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - } | |
08/27/2020 | COT - LCBU - Roof Nailing | Passed | {Activity date: 08/27/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Approved. } |
|
08/27/2020 | COT - BULD - SWG Clearance | Passed | {Activity date: 08/27/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - CODE} ; {Activity date: 04/20/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - CODE} | |
08/27/2020 | COT - LCBU - Building Progress | Passed | {Activity date: 08/27/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Approved. } |
|
09/09/2020 | COT - LCBU - Building Above Ceiling | Passed | {Activity date: 09/09/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Approved, corrections complete.} ; {Activity date: 09/08/2020; Status: Denied; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - Denied. Electrical MC is not secured 12 inches from electrical boxes. Electrical MC cable may not be supported by the sprinkler system and shall be supported every 6 feet. } ; {Activity date: 08/27/2020; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by JSCHNEI2 - Partial, Revision pending.} ; {Activity date: 08/14/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Partial. Showroom ceiling complete.} ; {Activity date: 08/03/2020; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - Not ready} ; {Activity date: 07/31/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Partial. Front radius ledge/ soffit area.} ; {Activity date: 07/30/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by JSCHNEI2 - Partial. Lower lid #105 service mgr’s office and #108 IT room. } ; {Activity date: 07/23/2020; Status: Partial Approval; Inspector: TTREBMULAK; Comment: Entered by RSALDAT1 - Partial. Soft lid above room 105, service managers office area.} ; {Activity date: 07/10/2020; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Partial, Service Drive Thru Ok to proceed.} ; {Activity date: 05/22/2020; Status: Partial Approval; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Partial. Outside service drive ceiling. Ok to enclose.} ; {Activity date: 05/18/2020; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - Partial approval delivery room only} ; {Activity date: 04/09/2020; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - RVI Partial. Restrooms, online sales office, finance office, retail parts and managers office, sales office and manager office, lounge area, café and mechanical closet.} ; {Activity date: 04/07/2020; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - } ; {Activity date: 03/04/2020; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by SFLORES2 - Ok to install hard lid south of gridline E} |