Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/15/2019 | PLANS OK TO SUBMIT - RES | 04/15/2019 | COMPLETED |
04/15/2019 | RESIDENTIAL - BLDG/WWM | 05/07/2019 | COMPLETED |
05/07/2019 | RESIDENTIAL - BLDG/WWM | 05/22/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM02654
Permit Status: Final
Permit Description: NEW SFR
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/15/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T19CM02654
Permit Description: NEW SFR
Total Completed Inspections - 22
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/03/2019 | PLUMBING - ROUGH, SOIL | JBURGE | Approved | OK within footprint of building. Revise plans to include gray water loop. |
06/10/2019 | BUILDING PRE-SLAB | TVALENCIA | Approved | |
06/10/2019 | EXCAVATION/LAYOUT REBAR & ZON | TVALENCIA | Approved | |
06/18/2019 | ELECTRIC - UFER | RCAMACHO | Approved | Install main feeders Consult with TEP on panel location over garage flat roof |
06/21/2019 | TEP CLEARANCE - PM | ESTEVENS | Approved | CODE ECO |
06/21/2019 | ELECTRIC - CONSTRUCTION POWER | ESTEVENS | Approved | The TEP clearance code is ECO. |
06/24/2019 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved | |
06/24/2019 | ROOF NAILING | JBURGE | Approved | Ok to dry in roof system. |
06/24/2019 | FRAMING | JBURGE | Approved | |
06/25/2019 | PLUMBING - SEWER HCS CONNECT | TVALENCIA | Approved | 1- Bldg. sewer is okay from sewer main to 5 feet of bldg. drain. Sewer main tap approved, tracer wire provided. |
07/26/2019 | PLUMBING - GAS PRESSURE TEST | TVALENCIA | Approved | |
07/30/2019 | MECHANICAL - INTERMEDIATE | ESTEVENS | Approved | |
07/30/2019 | PLUMBING - INTERMEDIATE | ESTEVENS | Approved | |
07/30/2019 | RESIDENTIAL INTERMEDIATE | ESTEVENS | Approved | |
08/13/2019 | SHEET ROCK NAILING | DQUINN | Approved | |
09/11/2019 | GAS CLEARANCE | TVALENCIA | Approved | |
09/17/2019 | BUILDING - FINAL | CTREVIL | Approved | NO FINAL MAY BE OBTAINED PRIOR TO COMPLETION OF SIDEWALK PER SEPARATE ACTIVITY. |
03/19/2020 | OUTDOOR LIGHTING FINAL | ESTEVENS | Approved | |
03/19/2020 | PLUMBING - YARD WTR LINE/TEST | ESTEVENS | Approved | |
03/24/2020 | MECHANICAL - FINAL | MRAMBER | Approved | |
03/24/2020 | PLUMBING - FINAL | MRAMBER | Approved | |
03/24/2020 | ELECTRIC - FINAL | MRAMBER | Approved |