Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Address:
4524 S 18TH AV
Address NEW:
4524 S 18TH AV
Apply Date:
04/01/2019
Applicant:
Description:
ENCLOSE CARPORT AND ADD PORCH IN THE BACK

Permit Reviews

Permit Number - T19CM02247
Permit Status: Expired
Permit Description: ENCLOSE CARPORT AND ADD PORCH IN THE BACK
Start Date Submittal Complete Date Status  
04/01/2019 RESIDENTIAL - BLDG/ZONING-WALKTHRU 04/01/2019 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T19CM02247
Permit Status: Expired
Permit Description: ENCLOSE CARPORT AND ADD PORCH IN THE BACK
Total Outstanding Activity Conditions - 1
Date Name
04/01/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T19CM02247
Permite Description: ENCLOSE CARPORT AND ADD PORCH IN THE BACK
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
11/04/2022 COT - RSEL - Service Relocation N/A Canceled Inspection Canceled
11/04/2022 COT - RSME - Mechanical Final N/A Canceled Inspection Canceled
11/04/2022 RSBU - Building Final N/A Canceled Inspection Canceled
11/04/2022 COT - RSEL - Service Upgrade N/A Canceled Inspection Canceled
11/04/2022 COT - RSEL - Electrical Final N/A Canceled Inspection Canceled
11/07/2022 COT - LCBU - Framing N/A Canceled Inspection Canceled

Completed Inspections

Permit Status: Expired
Permit Number: T19CM02247
Permit Description: ENCLOSE CARPORT AND ADD PORCH IN THE BACK
Total Completed Inspections - 5
Date Description Inspector Results Comments
10/02/2019 COT - RSBU - Preslab Passed {Activity date: 10/02/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } ; {Activity date: 04/11/2019; Status: Partial Approval; Inspector: RCAMACHO; Comment: Entered by CBELL1 - Rear porch only} ; {Activity date: 04/10/2019; Status: Partial Approval; Inspector: MHASSAN; Comment: Entered by CBELL1 - gas meter will now be located in patio slab. Need gas line exposed to make sure that it is sleeved before we pour concrete. Also construction of patio roof will lead to issues with existing electric riser being extremely low. This is a safety issue and will need to be addressed before getting to far. Recommend contacting TEP before proceeding.}
10/02/2019 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 10/02/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } ; {Activity date: 04/11/2019; Status: Partial Approval; Inspector: RCAMACHO; Comment: Entered by CBELL1 - Rear porch only} ; {Activity date: 04/11/2019; Status: Partial Approval; Inspector: RCAMACHO; Comment: Entered by CBELL1 - Rear porch only} ; {Activity date: 04/10/2019; Status: Partial Approval; Inspector: MHASSAN; Comment: Entered by CBELL1 - patio OK, carport work is not started yet}
11/27/2019 COT - RSBU - Roof Nailing Passed {Activity date: 11/27/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } ; {Activity date: 04/18/2019; Status: Partial Approval; Inspector: MHASSAN; Comment: Entered by CBELL1 - back porch only OK}
11/27/2019 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed {Activity date: 11/27/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } ; {Activity date: 04/18/2019; Status: Partial Approval; Inspector: MHASSAN; Comment: Entered by CBELL1 - back porch only OK}
12/18/2019 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 12/18/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } ; {Activity date: 11/27/2019; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - 1- Electric conductors and boxes are okay to cover the exterior walls only.
} ; {Activity date: 11/13/2019; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - 1- masonry first lift is okay for grout.}

Documents

File Name Document Type  
001_SHEET 1 OF 7.TIF CONSTRPLANS VIEW
002_SHEET 2 OF 7.TIF CONSTRPLANS VIEW
003_SHEET 3 OF 7.TIF CONSTRPLANS VIEW
004_SHEET 4 OF 7.TIF CONSTRPLANS VIEW
005_SHEET 5 OF 7.TIF CONSTRPLANS VIEW
006_SHET 6 OF 7.TIF CONSTRPLANS VIEW
007_SHEET 7 OF 7.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW