Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T19CM02130
Permit Details
Apply Date:
03/26/2019
Applicant:
Kimberly York
Description:
SFR KB201017 T17-M0030
Permit Reviews
Permit Number - T19CM02130
Permit Status: Expired
Permit Description: SFR KB201017 T17-M0030
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/26/2019 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 03/26/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM02130
Permit Status: Expired
Permit Description: SFR KB201017 T17-M0030
Total Outstanding Activity Conditions - 5
Date | Name |
---|---|
03/26/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
03/26/2019 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
03/26/2019 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
03/26/2019 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
03/26/2019 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM02130
Permit Description: SFR KB201017 T17-M0030
Total Completed Inspections - 22
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/02/2019 | COT - RSPL - Sewer | Passed | {Activity date: 04/02/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
04/02/2019 | COT - RSPL - Rough Soil | Passed | {Activity date: 04/02/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
04/11/2019 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 04/11/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
04/11/2019 | COT - RSBU - Preslab | Passed | {Activity date: 04/11/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
04/11/2019 | COT - RSEL - Electrical Underground | Passed | {Activity date: 04/11/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
04/11/2019 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 04/11/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
05/01/2019 | COT - RSBU - Roof Nailing | Passed | {Activity date: 05/01/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by CBELL1 - } ; {Activity date: 04/30/2019; Status: Denied; Inspector: DMUNIZ; Comment: Entered by CBELL1 - Work incomplete, see previous inspection results} ; {Activity date: 04/26/2019; Status: Denied; Inspector: DQUINN; Comment: Entered by CBELL1 - 1. Strap non cabin tied top plates at front porch. 2. Install mas anchors on front post. 3. Re -install front porch hanging frame where it doesn’t reach the garage. 4. osb not nailed at n.w. 2nd floor corner. 5. Several rows missed on patio roof. 6. Need ladder installed and tied off to upper roof for inspection. 7. Nail off osb in both studs at hold downs, all the way up.} ; {Activity date: 04/25/2019; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by CBELL1 - } |
|
05/01/2019 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 05/01/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by CBELL1 - CODE ECO} | |
05/01/2019 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 05/01/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by CBELL1 - } ; {Activity date: 04/30/2019; Status: Denied; Inspector: DMUNIZ; Comment: Entered by CBELL1 - Work incomplete, see previous inspection results} ; {Activity date: 04/26/2019; Status: Denied; Inspector: DQUINN; Comment: Entered by CBELL1 - 1. Strap non cabin tied top plates at front porch. 2. Install mas anchors on front post. 3. Re -install front porch hanging frame where it doesn’t reach the garage. 4. osb not nailed at n.w. 2nd floor corner. 5. Several rows missed on patio roof. 6. Need ladder installed and tied off to upper roof for inspection. 7. Nail off osb in both studs at hold downs, all the way up.} ; {Activity date: 04/25/2019; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by CBELL1 - } |
|
05/01/2019 | COT - RSEL - Construction Power | Passed | {Activity date: 05/01/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by CBELL1 - Clear eco} | |
05/20/2019 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 05/20/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
05/20/2019 | COT - LCBU - Framing | Passed | {Activity date: 05/20/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
05/20/2019 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 05/20/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
05/20/2019 | COT - RSPL - Yard Water Line | Passed | {Activity date: 05/20/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } ; {Activity date: 04/11/2019; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by CBELL1 - No test} ; {Activity date: 04/02/2019; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by CBELL1 - Line & Tracer ok no water meter} | |
05/20/2019 | RSME - Mechanical Progress | Passed | {Activity date: 05/20/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
06/07/2019 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 06/07/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } ; {Activity date: 06/06/2019; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - work incomplete upon arrival.} | |
07/03/2019 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 07/03/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Clear Southwest Gas} | |
07/19/2019 | COT - BULD - SWG Clearance | Passed | {Activity date: 07/19/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VFLORES1 - RESENDING GAS CLEARANCE} ; {Activity date: 07/03/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
08/02/2019 | COT - RSME - Mechanical Final | Passed | {Activity date: 08/02/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - } | |
08/02/2019 | RSBU - Building Final | Passed | {Activity date: 08/02/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Install PT tag on water riser } |
|
08/02/2019 | COT - RSPL - Plumbing Final | Passed | {Activity date: 08/02/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - } | |
08/02/2019 | COT - RSEL - Electrical Final | Passed | {Activity date: 08/02/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Install covers on outlets on kitchen island } |