Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T19CM01832
Permit Details
Apply Date:
03/13/2019
Applicant:
RICHMOND AMERICAN CONSTRUCTION INC
Description:
SFR RICHT90817 T17-M0036
Contractors:
- RICHMOND AMERICAN CONSTRUCTION INC
Permit Reviews
Permit Number - T19CM01832
Permit Status: Expired
Permit Description: SFR RICHT90817 T17-M0036
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/13/2019 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 03/13/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM01832
Permit Status: Expired
Permit Description: SFR RICHT90817 T17-M0036
Total Outstanding Activity Conditions - 3
Date | Name |
---|---|
03/13/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
03/13/2019 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
03/13/2019 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM01832
Permit Description: SFR RICHT90817 T17-M0036
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/20/2019 | PLUMBING - SEWER HCS CONNECT | DMUNIZ | Approved | |
03/20/2019 | PLUMBING - ROUGH, SOIL | DMUNIZ | Approved | |
04/02/2019 | ELECTRIC - UNDERGROUND | AKLEINSORGE | Approved | |
04/02/2019 | ELECTRIC - UFER | AKLEINSORGE | Approved | |
04/02/2019 | BUILDING PRE-SLAB | AKLEINSORGE | Approved | |
04/02/2019 | EXCAVATION/LAYOUT REBAR & ZON | AKLEINSORGE | Approved | |
04/09/2019 | ROOF NAILING | AKLEINSORGE | Approved | |
04/09/2019 | EXT METAL CLIPS/EXT SHEATHING | AKLEINSORGE | Approved | |
04/24/2019 | TEP CLEARANCE - PM | AKLEINSORGE | Approved | CODE ECO |
04/24/2019 | MECHANICAL - INTERMEDIATE | AKLEINSORGE | Approved | |
04/24/2019 | PLUMBING - GAS PRESSURE TEST | AKLEINSORGE | Approved | |
04/24/2019 | PLUMBING - YARD WTR LINE/TEST | AKLEINSORGE | Approved | |
04/24/2019 | ELECTRIC - CONSTRUCTION POWER | AKLEINSORGE | Approved | Clear eco |
04/24/2019 | FRAMING | AKLEINSORGE | Approved | |
04/25/2019 | PLUMBING - INTERMEDIATE | DQUINN | Approved | |
04/25/2019 | RESIDENTIAL INTERMEDIATE | DQUINN | Approved | |
05/01/2019 | SHEET ROCK NAILING | DMUNIZ | Approved | |
06/04/2019 | GAS CLEARANCE | AKLEINSORGE | Approved | |
06/10/2019 | MECHANICAL - FINAL | AKLEINSORGE | Approved | |
06/10/2019 | PLUMBING - FINAL | AKLEINSORGE | Approved | |
06/10/2019 | OUTDOOR LIGHTING FINAL | AKLEINSORGE | Approved | |
06/10/2019 | ELECTRIC - FINAL | AKLEINSORGE | Approved | |
06/10/2019 | BUILDING - FINAL | AKLEINSORGE | Approved |