Permit: T19BU00288
Permit Details
Apply Date:
06/03/2019
Applicant:
BONNEMA POOL AND SPAS
Description:
14x30 pool - 6x7 spa heater - 175 ft of 2" gas line - 10ft retainer wall - 80ft of 5ft wall - 20 ft of W/I - auto cover gates
Contractors:
- BONNEMA COMPANY INC , THE
Permit Reviews
Permit Number - T19BU00288
Permit Status: Closed
Permit Description: 14x30 pool - 6x7 spa heater - 175 ft of 2" gas line - 10ft retainer wall - 80ft of 5ft wall - 20 ft of W/I - auto cover gates
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/03/2019 | POOL - SPA | 06/03/2019 | COMPLETED |
Outstanding Inspections
Permit Status: Closed
Permit Number: T19BU00288
Permite Description: 14x30 pool - 6x7 spa heater - 175 ft of 2" gas line - 10ft retainer wall - 80ft of 5ft wall - 20 ft of W/I - auto cover gates
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
POOL/SPA HEATER | N/A | Not Inspected | ||
02/21/2020 | POOL/SPA FINAL/BARRIER | N/A | Not ready for Inspection | |
08/20/2019 | POOL/SPA GAS | N/A | Partial Approval | 1- Gas pressure test was provided for underground gas line. 2- Shall provide clean fill rock free for backfilling of gas line. |
11/21/2019 | REINFORCED MASONRY PRE-GROUT | N/A | Partial Approval | Southeast corner. |
Completed Inspections
Permit Status: Closed
Permit Number: T19BU00288
Permit Description: 14x30 pool - 6x7 spa heater - 175 ft of 2" gas line - 10ft retainer wall - 80ft of 5ft wall - 20 ft of W/I - auto cover gates
Total Completed Inspections - 9
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/26/2019 | POOL/SPA PRE-GUNITE | MHASSAN | Approved | after speaking with pool designer, contractor did meet minimum requirements on freestanding pool footing, although did not build exactly per detail. |
07/26/2019 | POOL/SPA PRE-GUNITE | MHASSAN | Approved | freestanding wall portion, one detail shows a footing and the other detail does not show a footing please verify which one is correct with the engineer as the current wall footing is not per detail. |
07/26/2019 | POOL/SPA BONDING GRID | MHASSAN | Approved | |
07/26/2019 | POOL/SPA ELECTRIC | MHASSAN | Approved | |
07/26/2019 | POOL/SPA PLUMBING | MHASSAN | Approved | |
10/30/2019 | STEM WALL/RETAINING WALL | ESTEVENS | Approved | |
10/30/2019 | EXCAVATION/LAYOUT REBAR & ZON | ESTEVENS | Approved | |
03/11/2020 | GAS CLEARANCE | TVALENCIA | Approved | |
03/11/2020 | BUILDING - FINAL | TVALENCIA | Approved | 1- I recommend that the West gate and patio wall be access proof by stepping over the barrier even though an approved cover has been provided. 2- Clear gas meter Verbal clearance called in at 11:28am |