Permit: T18FC00372
Permit Details
Apply Date:
05/02/2018
Applicant:
Description:
Automatic Fire Extingshing Sys - BLDG #2 - INSTALL NEW FIRE SPRINKLER SYSTEM; Commercial Fire Sprinkler Systems - Standpipe New Outlets: 16; Additional Inspections: 5
Outstanding Inspections
Permit Status: Expired
Permit Number: T18FC00372
Permite Description: Automatic Fire Extingshing Sys - BLDG #2 - INSTALL NEW FIRE SPRINKLER SYSTEM; Commercial Fire Sprinkler Systems - Standpipe New Outlets: 16; Additional Inspections: 5
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/14/2019 | COT - FCON - Sprinkler - Final | N/A | Partial Pass | {Activity date: 05/14/2019; Status: Partial Approval; Inspector: JPEELDAVIS; Comment: Entered by JPEELDA1 - Tested the fire pump. The fire pump passed the inspection, however, the signals could not be verifyed to the fire alarm system so the fire pump is locked out until the signals can be confirmed. Need to verify that the fire pump, water flow and tamper signals are reportting off site prior to approving a TCO for fixturing of the building.} |
Completed Inspections
Permit Status: Expired
Permit Number: T18FC00372
Permit Description: Automatic Fire Extingshing Sys - BLDG #2 - INSTALL NEW FIRE SPRINKLER SYSTEM; Commercial Fire Sprinkler Systems - Standpipe New Outlets: 16; Additional Inspections: 5
Total Completed Inspections - 1
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/17/2019 | FCON – OH Piping & Hydro | Passed | {Activity date: 04/17/2019; Status: Approved; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - All floors have now been completed for OH Piping & Hydro.} ; {Activity date: 10/11/2018; Status: Partial Approval; Inspector: JPEELDAVIS; Comment: Entered by CBASALD1 - Bldg 2, Level 1. Inspected 6 units on the south side.} ; {Activity date: 10/23/2018; Status: Partial Approval; Inspector: jvincent; Comment: Entered by CBASALD1 - Bldg 2, Level 1. Rooms 2101-2107.} ; {Activity date: 01/03/2019; Status: Partial Approval; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - Bldg 2, Level 6. Rooms 2602-2607 & 2613, 2615, 2616, 2618.} ; {Activity date: 04/16/2019; Status: Partial Approval; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - Hydro test for Standpipes.} ; {Activity date: 03/26/2019; Status: Partial Approval; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - Bldg 2, Level 4 Parking Garage} ; {Activity date: 02/07/2019; Status: Partial Approval; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - Bldg 2, Level 6. Area B Amenities.} ; {Activity date: 02/07/2019; Status: Partial Approval; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - Bldg 2, Level 6. Rooms 2611-2612.} ; {Activity date: 01/31/2019; Status: Partial Approval; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - Bldg 2, Level 8. Rooms 2802-2808 & 2811-1818.} ; {Activity date: 01/23/2019; Status: Partial Approval; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - Bldg 2, Level 7. Rooms 2702-2708 & 2711-2718.} ; {Activity date: 12/27/2018; Status: Partial Approval; Inspector: jvincent; Comment: Entered by JVINCEN1 - OH/hydro approved for 2501-2507, 2513-2518.} ; {Activity date: 12/11/2018; Status: Partial Approval; Inspector: JPEELDAVIS; Comment: Entered by JPEELDA1 - 4th floor OH Hydro @ 205 psi - Approved} ; {Activity date: 11/15/2018; Status: Partial Approval; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - Bldg 2, Level 3. Rooms 2301-2307 & 2313-2318.} ; {Activity date: 10/30/2018; Status: Partial Approval; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - Bldg 2, Level 2. Rooms 2201-2207 & 2213-2218.} |