Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T18CM08668
Permit Details
Apply Date:
10/30/2018
Applicant:
Description:
SFR LEN400418 T18-M0080
Permit Reviews
Permit Number - T18CM08668
Permit Status: Expired
Permit Description: SFR LEN400418 T18-M0080
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/29/2019 | REVISION - - 1ST | 01/29/2019 | COMPLETED |
10/30/2018 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 10/30/2018 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T18CM08668
Permit Status: Expired
Permit Description: SFR LEN400418 T18-M0080
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/30/2018 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Conditions
Permit Number - T18CM08668
Permit Status: Expired
Permit Description: SFR LEN400418 T18-M0080
Date | Description | Comments |
---|---|---|
10/30/2018 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
Completed Inspections
Permit Status: Expired
Permit Number: T18CM08668
Permit Description: SFR LEN400418 T18-M0080
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/28/2018 | COT - RSPL - Yard Water Line | Passed | {Activity date: 11/28/2018; Status: Approved; Inspector: BJONES; Comment: Entered by CBELL1 - } | |
11/28/2018 | COT - RSPL - Sewer | Passed | {Activity date: 11/28/2018; Status: Approved; Inspector: BJONES; Comment: Entered by CBELL1 - } | |
11/28/2018 | COT - RSPL - Rough Soil | Passed | {Activity date: 11/28/2018; Status: Approved; Inspector: BJONES; Comment: Entered by CBELL1 - } | |
12/10/2018 | COT - RSEL - Electrical Underground | Passed | {Activity date: 12/10/2018; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
12/10/2018 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 12/10/2018; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
12/10/2018 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 12/10/2018; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
12/28/2018 | COT - RSBU - Roof Nailing | Passed | {Activity date: 12/28/2018; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } ; {Activity date: 12/27/2018; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by CBELL1 - Need ladder for roof access} ; {Activity date: 12/26/2018; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by CBELL1 - WORK INCOMPLETE} | |
01/24/2019 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 01/24/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } ; {Activity date: 12/10/2018; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by CBELL1 - STUB UP OK 20'} | |
01/24/2019 | RSEL - Electrical Progress | Passed | {Activity date: 01/24/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
01/24/2019 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 01/24/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
01/25/2019 | COT - LCBU - Framing | Passed | {Activity date: 01/25/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } ; {Activity date: 01/24/2019; Status: Denied; Inspector: DMUNIZ; Comment: Entered by CBELL1 - NAIL H2.5 EAST BEARING WALL, FOAM ALL TOP PLATE PENETRATIONS.} ; {Activity date: 12/28/2018; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by CBELL1 - SHALL BE CALLED IN WITH ALL INTERMEDIATES.} ; {Activity date: 12/27/2018; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by CBELL1 - Intermediates must be complete before frame inspection} ; {Activity date: 12/26/2018; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by CBELL1 - WORK INCOMPLETE} | |
01/25/2019 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 01/25/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } ; {Activity date: 01/24/2019; Status: Denied; Inspector: DMUNIZ; Comment: Entered by CBELL1 - STRAP GAS LINE WHERE NEEDED.} | |
01/25/2019 | RSME - Mechanical Progress | Passed | {Activity date: 01/25/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } ; {Activity date: 01/24/2019; Status: Denied; Inspector: DMUNIZ; Comment: Entered by CBELL1 - NEED 1" CLEARANCE ON HW B-VENT} | |
01/30/2019 | COT - RSBU - Preslab | Passed | {Activity date: 01/30/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
01/30/2019 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 01/30/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
02/15/2019 | PDSD Building Division - TEP PMÂ Clearance | Passed | {Activity date: 02/15/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - CODE ECO} | |
02/15/2019 | COT - RSEL - Construction Power | Passed | {Activity date: 02/15/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - CLEAR ECO} | |
03/28/2019 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 03/28/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
03/28/2019 | COT - RSPL - Plumbing Final | Passed | {Activity date: 03/28/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } | |
04/01/2019 | COT - RSME - Mechanical Final | Passed | {Activity date: 04/01/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by CBELL1 - } ; {Activity date: 03/28/2019; Status: Denied; Inspector: DMUNIZ; Comment: Entered by CBELL1 - Electrical Whips from condenser to disconnects must be tied in. Insulate Condensation lines, Install combustion & Relief vents. Provide ladder to access Attic for further inspection. Missing weather head for dryer vent on roof.} | |
04/01/2019 | RSBU - Building Final | Passed | {Activity date: 04/01/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by CBELL1 - } ; {Activity date: 03/28/2019; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by CBELL1 - work incomplete.} | |
04/01/2019 | COT - RSEL - Electrical Final | Passed | {Activity date: 04/01/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by CBELL1 - } ; {Activity date: 03/28/2019; Status: Denied; Inspector: DMUNIZ; Comment: Entered by CBELL1 - Label circuit breakers in Electrical panel. Phase tape white conductors black to identify Hot. Provide K/O seal under panel. Troubleshoot sales office GFCI when reset it trips the main breaker.} | |
04/03/2019 | COT - BULD - SWG Clearance | Passed | {Activity date: 04/03/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by CBELL1 - } |