Permit: T18CM05591
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
7002 E ELBOW BAY DR
Address NEW:
7002 E ELBOW BAY DR
Apply Date:
07/18/2018
Applicant:
AGILE PLUMBING SEWER & DRAIN LLC
Description:
INTERIOR REPIPE, NEW WAER LINE, GAS LINE REPAIR, RELOCATE WATER HEATER
Contractors:
- AGILE PLUMBING SEWER & DRAIN LLC
Permit Reviews
Permit Number - T18CM05591
Permit Status: Expired
Permit Description: INTERIOR REPIPE, NEW WAER LINE, GAS LINE REPAIR, RELOCATE WATER HEATER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/18/2018 | WALK THRU - RES | 07/18/2018 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T18CM05591
Permit Status: Expired
Permit Description: INTERIOR REPIPE, NEW WAER LINE, GAS LINE REPAIR, RELOCATE WATER HEATER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/18/2018 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T18CM05591
Permite Description: INTERIOR REPIPE, NEW WAER LINE, GAS LINE REPAIR, RELOCATE WATER HEATER
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/27/2018 | PLUMBING - INTERMEDIATE | N/A | Correction Required | Water Heater: Bvent to have 1" min clearance on all sides where itpenetrated the eave sheathing and roof cover. Install and seat the concrete water meter baox per COT Water Dept Requirements. Paint all exposed black iron gas pipe with protective paint.. Water lines at far left exterior at rear of house-Seal the escutheons to the wall to prevent moisture entering the exterior wall. Substantial amount oif gas lines added or replaced. Where is the GAT gauge located for inspection? |
| 07/27/2018 | PLUMBING - GAS PRESSURE TEST | N/A | Correction Required | See Corrections! |
| 07/27/2018 | PLUMBING - FINAL | N/A | Correction Required | Not ready for Final |
Completed Inspections
Permit Status: Expired
Permit Number: T18CM05591
Permit Description: INTERIOR REPIPE, NEW WAER LINE, GAS LINE REPAIR, RELOCATE WATER HEATER
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/19/2018 | PLUMBING - YARD WTR LINE/TEST | TVALENC1 | Approved | IVRS - Inspection :* |