Permit: T18CM05176
Permit Details
Status:
Final
Type:
SINGLE FAMILY NEW
Address:
6438 E VIA ARROYO LARGO
Address NEW:
6438 E VIA ARROYO LARGO
Apply Date:
07/02/2018
Applicant:
RICHMOND AMERICAN CONSTRUCTION INC
Description:
SFR RICHT90317 T17-M0034
Contractors:
- RICHMOND AMERICAN CONSTRUCTION INC
Permit Reviews
Permit Number - T18CM05176
Permit Status: Final
Permit Description: SFR RICHT90317 T17-M0034
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/02/2018 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/02/2018 | ACTIVE |
Outstanding Activity Conditions
Permit Number - T18CM05176
Permit Status: Final
Permit Description: SFR RICHT90317 T17-M0034
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/02/2018 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T18CM05176
Permit Description: SFR RICHT90317 T17-M0034
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2018 | PLUMBING - ROUGH, SOIL | MHASSAN1 | Approved | |
| 07/17/2018 | PLUMBING - SEWER HCS CONNECT | MHASSAN1 | Approved | |
| 07/25/2018 | ELECTRIC - UNDERGROUND | MHASSAN1 | Approved | IVRS - Inspection :* INSTALL MISSING CONDUIT TO ISLAND |
| 07/25/2018 | BUILDING PRE-SLAB | MHASSAN1 | Approved | IVRS - Inspection :* |
| 07/25/2018 | EXCAVATION/LAYOUT REBAR & ZON | MHASSAN1 | Approved | IVRS - Inspection :* |
| 08/13/2018 | ROOF NAILING | TVALENC1 | Approved | IVRS - Inspection :* |
| 08/13/2018 | EXT METAL CLIPS/EXT SHEATHING | TVALENC1 | Approved | IVRS - Inspection :* |
| 09/17/2018 | MECHANICAL - INTERMEDIATE | BJONES | Approved | |
| 09/17/2018 | ELECTRIC - INTERMEDIATE | BJONES | Approved | relocate PEX to 12 inches away from can lights. waste pipe must slope a quarter of an inch per foot downhill |
| 09/18/2018 | ELECTRIC - CONSTRUCTION POWER | TVALENC1 | Approved | IVRS - Inspection :* 1- CLEAR ELECTRIC ECO |
| 09/18/2018 | PLUMBING - GAS PRESSURE TEST | TVALENC1 | Approved | IVRS - Inspection :* |
| 09/18/2018 | PLUMBING - INTERMEDIATE | TVALENC1 | Approved | IVRS - Inspection :* |
| 09/18/2018 | ELECTRIC - CABLE DROP | TVALENC1 | Approved | IVRS - Inspection :* |
| 09/19/2018 | TEP CLEARANCE - AM | TVALENCIA | Approved | ECO |
| 10/04/2018 | SHEET ROCK NAILING | TVALENC1 | Approved | |
| 10/31/2018 | GAS CLEARANCE | TVALENCIA | Approved | |
| 11/08/2018 | PLUMBING - PROGRESS | TVALENCIA | Approved | |
| 11/08/2018 | PLUMBING - YARD WTR LINE/TEST | TVALENCIA | Approved | |
| 11/08/2018 | ELECTRIC - UFER | TVALENCIA | Approved | |
| 11/08/2018 | U VALUE FOR WINDOW | TVALENCIA | Approved | |
| 11/08/2018 | STUCCO MESH | TVALENCIA | Approved | |
| 11/08/2018 | FRAMING | TVALENCIA | Approved | |
| 11/08/2018 | MECHANICAL - FINAL | TVALENCIA | Approved | |
| 11/08/2018 | PLUMBING - FINAL | TVALENCIA | Approved | |
| 11/08/2018 | OUTDOOR LIGHTING FINAL | TVALENCIA | Approved | |
| 11/08/2018 | ELECTRIC - FINAL | TVALENCIA | Approved | |
| 11/08/2018 | BUILDING - FINAL | TVALENCIA | Approved |