Permit Reviews
Permit Number - T18CM04566
Permit Status: Final
Permit Description: SFR PLAN2375 T16-M0006
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/12/2018 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 06/12/2018 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T18CM04566
Permit Status: Final
Permit Description: SFR PLAN2375 T16-M0006
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/12/2018 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T18CM04566
Permit Description: SFR PLAN2375 T16-M0006
Total Completed Inspections - 27
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/05/2018 | PLUMBING - SEWER HCS CONNECT | MHASSAN1 | Approved | |
07/05/2018 | PLUMBING - YARD WTR LINE/TEST | MHASSAN1 | Approved | |
07/05/2018 | PLUMBING - ROUGH, SOIL | MHASSAN1 | Approved | |
07/11/2018 | ELECTRIC - UNDERGROUND | MHASSAN1 | Approved | |
07/11/2018 | BUILDING PRE-SLAB | MHASSAN1 | Approved | |
07/11/2018 | EXCAVATION/LAYOUT REBAR & ZON | MHASSAN1 | Approved | |
07/27/2018 | EXT METAL CLIPS/EXT SHEATHING | MHASSAN1 | Approved | |
07/30/2018 | ROOF NAILING | MHASSAN1 | Approved | |
08/02/2018 | ELECTRIC - CABLE DROP | MHASSAN1 | Approved | OK TO CLEAR ELECTRIC, TMPP |
08/02/2018 | ELECTRIC - UFER | MHASSAN1 | Approved | |
08/03/2018 | TEP CLEARANCE - AM | MHASSAN | Approved | TMPP |
08/13/2018 | PLUMBING - GAS PRESSURE TEST | TVALENC1 | Approved | IVRS - Inspection :* |
08/13/2018 | MECHANICAL - INTERMEDIATE | TVALENC1 | Approved | IVRS - Inspection :* |
08/13/2018 | PLUMBING - INTERMEDIATE | TVALENC1 | Approved | IVRS - Inspection :* |
08/13/2018 | ELECTRIC - INTERMEDIATE | TVALENC1 | Approved | IVRS - Inspection :* |
08/13/2018 | U VALUE FOR WINDOW | TVALENC1 | Approved | IVRS - Inspection :* |
08/13/2018 | STUCCO MESH | TVALENC1 | Approved | IVRS - Inspection :* |
08/13/2018 | FRAMING | TVALENC1 | Approved | IVRS - Inspection :* |
09/06/2018 | SHEET ROCK NAILING | TVALENC1 | Approved | IVRS - Inspection :* |
10/16/2018 | GAS CLEARANCE | TVALENCIA | Approved | |
10/24/2018 | SITE - SEWER | TVALENCIA | Approved | |
10/24/2018 | PLUMBING - GAS PRESS TEST FNL | TVALENCIA | Approved | |
10/24/2018 | PLUMBING - PRE SLAB | TVALENCIA | Approved | |
10/24/2018 | MECHANICAL - FINAL | TVALENCIA | Approved | |
10/24/2018 | PLUMBING - FINAL | TVALENCIA | Approved | |
10/24/2018 | ELECTRIC - FINAL | TVALENCIA | Approved | |
10/24/2018 | BUILDING - FINAL | TVALENCIA | Approved |