Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY NEW
Apply Date:
04/26/2018
Applicant:
RICHMOND AMERICAN CONSTRUCTION INC
Description:
SFR RICHT90817 T17-M0036
Contractors:
  • RICHMOND AMERICAN CONSTRUCTION INC

Permit Reviews

Permit Number - T18CM03176
Permit Status: Expired
Permit Description: SFR RICHT90817 T17-M0036
Start Date Submittal Complete Date Status  
04/26/2018 RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU 05/01/2018 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T18CM03176
Permit Status: Expired
Permit Description: SFR RICHT90817 T17-M0036
Total Outstanding Activity Conditions - 2
Date Name
04/26/2018 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
04/26/2018 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Completed Inspections

Permit Status: Expired
Permit Number: T18CM03176
Permit Description: SFR RICHT90817 T17-M0036
Total Completed Inspections - 26
Date Description Inspector Results Comments
05/11/2018 PLUMBING - SEWER HCS CONNECT MHASSAN1 Approved
05/11/2018 PLUMBING - YARD WTR LINE/TEST MHASSAN1 Approved
05/11/2018 PLUMBING - ROUGH, SOIL MHASSAN1 Approved
05/16/2018 BUILDING PRE-SLAB DQUINN Approved
05/16/2018 EXCAVATION/LAYOUT REBAR & ZON DQUINN Approved
05/23/2018 ELECTRIC - UNDERGROUND MHASSAN1 Approved
06/07/2018 ROOF NAILING MHASSAN1 Approved
06/07/2018 EXT METAL CLIPS/EXT SHEATHING MHASSAN1 Approved MAKE SURE GABLE BRACING IS PER DETAIL ON DRAWINGS
07/06/2018 ELECTRIC - UFER MHASSAN1 Approved
07/06/2018 ELECTRIC - CABLE DROP MHASSAN1 Approved OK TO CLEAR ELECTRIC, TMPP
07/06/2018 ELECTRIC - CONSTRUCTION POWER MHASSAN1 Approved
07/09/2018 TEP CLEARANCE - AM MHASSAN Approved TMPP
07/09/2018 MECHANICAL - INTERMEDIATE MHASSAN1 Approved
07/09/2018 PLUMBING - GAS PRESSURE TEST MHASSAN1 Approved
07/09/2018 ELECTRIC - INTERMEDIATE MHASSAN1 Approved
07/09/2018 U VALUE FOR WINDOW MHASSAN1 Approved
07/09/2018 STUCCO MESH MHASSAN1 Approved FINISH WORK AT ENTRY
07/10/2018 PLUMBING - INTERMEDIATE MHASSAN1 Approved STILL NEED TO CORRECT THE FLU PIPING CLEARANCE WHERE IT PENETRATES THE ROOF
07/10/2018 FRAMING MHASSAN1 Approved
07/20/2018 SHEET ROCK NAILING MHASSAN1 Approved
08/16/2018 PLUMBING - FINAL GWest Approved
08/21/2018 GAS CLEARANCE GWest Approved GAT approved and clearance sent 8-21-2018 AM, GWest
08/27/2018 MECHANICAL - FINAL bjones Approved
08/27/2018 OUTDOOR LIGHTING FINAL bjones Approved
08/27/2018 ELECTRIC - FINAL bjones Approved
08/27/2018 BUILDING - FINAL bjones Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW