Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T18CM02889
Permit Details
Apply Date:
04/18/2018
Applicant:
MERITAGE HOMES
Description:
SFR PLAN2910 T16-M0005
Contractors:
- MERITAGE HOMES CONSTRUCTION INC *** APA***
Permit Reviews
Permit Number - T18CM02889
Permit Status: Expired
Permit Description: SFR PLAN2910 T16-M0005
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/18/2018 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 04/18/2018 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T18CM02889
Permit Status: Expired
Permit Description: SFR PLAN2910 T16-M0005
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
04/18/2018 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
04/18/2018 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T18CM02889
Permit Description: SFR PLAN2910 T16-M0005
Total Completed Inspections - 27
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/25/2018 | SITE - SEWER | MHASSAN1 | Approved | |
05/25/2018 | PLUMBING - SEWER HCS CONNECT | MHASSAN1 | Approved | |
05/25/2018 | PLUMBING - YARD WTR LINE/TEST | MHASSAN1 | Approved | |
05/25/2018 | PLUMBING - ROUGH, SOIL | MHASSAN1 | Approved | DOUBLECHECK 2" LINE NW CORNER FOR POSSIBLE LEAK. |
06/01/2018 | BUILDING PRE-SLAB | MHASSAN1 | Approved | |
06/01/2018 | EXCAVATION/LAYOUT REBAR & ZON | MHASSAN1 | Approved | |
06/04/2018 | ELECTRIC - UNDERGROUND | MHASSAN1 | Approved | |
06/25/2018 | ROOF NAILING | DQUINN | Approved | |
06/27/2018 | EXT METAL CLIPS/EXT SHEATHING | DQUINN | Approved | |
07/05/2018 | ELECTRIC - UFER | MHASSAN1 | Approved | |
07/05/2018 | ELECTRIC - CABLE DROP | MHASSAN1 | Approved | OK TO CLEAR ELECTRIC, TMPP |
07/06/2018 | TEP CLEARANCE - AM | MHASSAN | Approved | TMPP |
07/23/2018 | MECHANICAL - INTERMEDIATE | MHASSAN1 | Approved | IVRS - Inspection :* |
07/23/2018 | PLUMBING - GAS PRESSURE TEST | MHASSAN1 | Approved | IVRS - Inspection :* |
07/23/2018 | PLUMBING - INTERMEDIATE | MHASSAN1 | Approved | IVRS - Inspection :* |
07/23/2018 | ELECTRIC - INTERMEDIATE | MHASSAN1 | Approved | IVRS - Inspection :* |
07/23/2018 | FRAMING | MHASSAN1 | Approved | IVRS - Inspection :* |
08/15/2018 | SHEET ROCK NAILING | TVALENC1 | Approved | IVRS - Inspection :* |
09/17/2018 | PLUMBING - GAS PRESS TEST FNL | BJONES | Approved | |
09/18/2018 | GAS CLEARANCE | BJONES | Approved | |
09/25/2018 | PLUMBING - PRE SLAB | TVALENC1 | Approved | |
09/25/2018 | STUCCO MESH | TVALENC1 | Approved | |
09/25/2018 | U VALUE FOR WINDOW | TVALENC1 | Approved | |
09/25/2018 | MECHANICAL - FINAL | TVALENC1 | Approved | IVRS - Inspection :* |
09/25/2018 | PLUMBING - FINAL | TVALENC1 | Approved | IVRS - Inspection :* |
09/25/2018 | ELECTRIC - FINAL | TVALENC1 | Approved | IVRS - Inspection :* |
09/25/2018 | BUILDING - FINAL | TVALENC1 | Approved | IVRS - Inspection :* |