Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T18CM02659
Permit Details
Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
11 N TUCSON TE
Address NEW:
11 N TUCSON TE
Apply Date:
04/11/2018
Applicant:
Tom Kirschner
Description:
REMODEL SFR; REMODEL KITCHEN AND DINING ROOM; ENCLOSE SUNROOM
Permit Reviews
Permit Number - T18CM02659
Permit Status: Inspections complete
Permit Description: REMODEL SFR; REMODEL KITCHEN AND DINING ROOM; ENCLOSE SUNROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/11/2018 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 04/18/2018 | COMPLETED |
| 04/18/2018 | RESIDENTIAL - BLDG/WWM | 05/03/2018 | COMPLETED |
| 11/12/2019 | REVISION - - 1ST | 11/12/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T18CM02659
Permit Status: Inspections complete
Permit Description: REMODEL SFR; REMODEL KITCHEN AND DINING ROOM; ENCLOSE SUNROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/11/2018 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: T18CM02659
Permite Description: REMODEL SFR; REMODEL KITCHEN AND DINING ROOM; ENCLOSE SUNROOM
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/16/2019 | COT - RSBU - Roof Nailing | N/A | Canceled | {Activity date: 10/16/2019; Status: Not Applicable; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } |
| 10/16/2019 | COT - RSBU - Preslab | N/A | Canceled | {Activity date: 10/16/2019; Status: Not Applicable; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } |
| 10/16/2019 | COT - RSBU - Stem Wall/Retaining Wall | N/A | Canceled | {Activity date: 10/16/2019; Status: Not Applicable; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } |
| 10/16/2019 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Canceled | {Activity date: 10/16/2019; Status: Not Applicable; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } |
| 10/16/2019 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Canceled | {Activity date: 10/16/2019; Status: Not Applicable; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } |
| 10/16/2019 | COT - RSBU - Masonry Pregrout | N/A | Canceled | {Activity date: 10/16/2019; Status: Not Applicable; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: T18CM02659
Permit Description: REMODEL SFR; REMODEL KITCHEN AND DINING ROOM; ENCLOSE SUNROOM
Total Completed Inspections - 11
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/15/2019 | COT - RSPL - Rough Soil | Passed | {Activity date: 04/15/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } | |
| 04/26/2019 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 04/26/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } | |
| 04/26/2019 | RSEL - Electrical Progress | Passed | {Activity date: 04/26/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } | |
| 05/02/2019 | COT - LCBU - Framing | Passed | {Activity date: 05/02/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } | |
| 05/09/2019 | RSME - Mechanical Progress | Passed | {Activity date: 05/09/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by VFLORES1 - } | |
| 10/16/2019 | COT - RSME - Mechanical Final | Passed | {Activity date: 10/16/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
| 10/16/2019 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 10/16/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
| 10/16/2019 | COT - RSPL - Plumbing Final | Passed | {Activity date: 10/16/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
| 10/16/2019 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 10/16/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
| 10/16/2019 | COT - RSEL - Electrical Final | Passed | {Activity date: 10/16/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
| 12/12/2019 | RSBU - Building Final | Passed | {Activity date: 12/12/2019; Status: Approved; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/16/2019; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by DMERANZ1 - New garage and dining and kitchen expansion deleted from plan. No exterior work done. New baths, kitchen, laundry room, and window walls on east porch ok. Submit as-builts for review and close permit with as-builts approval.} |