Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
4850 E 28TH ST
Address NEW:
4850 E 28TH ST
Apply Date:
03/15/2018
Applicant:
CHARLEY ANDERSON
Description:
ADDITION: DINNING ROOM & BEDROOM & LAUNDRY ROOM

Permit Reviews

Permit Number - T18CM01976
Permit Status: Final
Permit Description: ADDITION: DINNING ROOM & BEDROOM & LAUNDRY ROOM
Start Date Submittal Complete Date Status  
03/15/2018 RESIDENTIAL - BLDG/ZONING-WALKTHRU 03/15/2018 COMPLETED Review Details
11/09/2018 REVISION - - 1ST 11/09/2018 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T18CM01976
Permit Status: Final
Permit Description: ADDITION: DINNING ROOM & BEDROOM & LAUNDRY ROOM
Total Outstanding Activity Conditions - 1
Date Name
03/15/2018 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T18CM01976
Permit Description: ADDITION: DINNING ROOM & BEDROOM & LAUNDRY ROOM
Total Completed Inspections - 19
Date Description Inspector Results Comments
05/16/2018 PLUMBING - ROUGH, SOIL BJones Approved
05/17/2018 EXCAVATION/LAYOUT REBAR & ZON BJONES Approved
05/18/2018 BUILDING PRE-SLAB BJONES Approved
06/14/2018 ROOF NAILING GWest Approved Roof Sheathing and nailing approved, 6-14-2018, GWest
06/22/2018 EXT METAL CLIPS/EXT SHEATHING GWest Approved Correct and Proceed: Anchor bolts, one each end of exterior wall sole plate at step down wall by W/H cabinet. All exterior or bearing walls require anchor bolts within 8" of plate ends.
08/06/2018 ELECTRIC - SERVICE UPGRADE GWest Approved New panel placed on addition wall to take the place of temp power. GWest 8-6-2018. Power Kill. Tep=Increase 100-200.
08/06/2018 ELECTRIC - UFER GWest Approved Ufer was cut off by framers. at panel upgrade 2 rods were installed to make up for the cut off UFER.
08/06/2018 ELECTRIC - INTERMEDIATE GWest Approved
08/07/2018 TEP CLEARANCE - AM GWEST Approved INCR
08/13/2018 MECHANICAL - INTERMEDIATE MHASSAN1 Approved
08/13/2018 PLUMBING - INTERMEDIATE MHASSAN1 Approved
08/13/2018 U VALUE FOR WINDOW MHASSAN1 Approved
08/13/2018 STUCCO MESH MHASSAN1 Approved SHIP LAP SIDING, NO STUCCO MESH
08/13/2018 FRAMING MHASSAN1 Approved EXTERIOR SHIP LAP SIDING NOT INSTALLED AT TIME OF INTERMEDIATE INSPECTIONS. IT IS NOT RECOMMENDED TO COVER UP THE WALLS DUE TO NAILS PENETRATING WIRES/PIPING. HOWEVER INTERMEDIATES ARE APPROVED.
12/14/2018 MECHANICAL - FINAL RCHANDLER Approved
12/14/2018 PLUMBING - GAS PRESSURE TEST RCHANDLER Approved approved upon 3090 approval from Robert C
12/14/2018 PLUMBING - FINAL RCHANDLER Approved
12/14/2018 ELECTRIC - FINAL RCHANDLER Approved
12/14/2018 BUILDING - FINAL RCHANDLER Approved

Documents

File Name Document Type  
001_C1.TIF CONSTRPLANS VIEW
002_A1.TIF CONSTRPLANS VIEW
003_A2.TIF CONSTRPLANS VIEW
004_A3.TIF CONSTRPLANS VIEW
005_SHEET M.TIF CONSTRPLANS VIEW
006_SHEET E.TIF CONSTRPLANS VIEW
007_SHEET E.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW