Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY NEW
Address NEW:
1866 N LEIGHTON PL
Apply Date:
03/05/2018
Applicant:
MIRAMONTE ARIZONA L L C *APA*
Description:
SFR SETONA16 T16-M0002
Contractors:
  • MIRAMONTE ARIZONA L L C *APA*

Permit Reviews

Permit Number - T18CM01691
Permit Status: Expired
Permit Description: SFR SETONA16 T16-M0002
Start Date Submittal Complete Date Status  
03/05/2018 RESIDENTIAL - BLDG/ZONING-WALKTHRU 03/05/2018 COMPLETED Review Details
03/06/2018 REVISION - - 1ST 03/06/2018 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T18CM01691
Permit Status: Expired
Permit Description: SFR SETONA16 T16-M0002
Total Outstanding Activity Conditions - 3
Date Name
03/05/2018 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
03/05/2018 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
03/05/2018 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.

Completed Inspections

Permit Status: Expired
Permit Number: T18CM01691
Permit Description: SFR SETONA16 T16-M0002
Total Completed Inspections - 28
Date Description Inspector Results Comments
04/11/2018 PLUMBING - SEWER HCS CONNECT DFLORES2 Approved
04/11/2018 PLUMBING - YARD WTR LINE/TEST DFLORES2 Approved
04/11/2018 PLUMBING - ROUGH, SOIL DFLORES2 Approved
04/16/2018 ELECTRIC - UNDERGROUND JBURGE Approved
04/16/2018 ELECTRIC - UFER JBURGE Approved
04/16/2018 BUILDING PRE-SLAB JBURGE Approved
04/16/2018 EXCAVATION/LAYOUT REBAR & ZON JBURGE Approved
06/12/2018 EXT METAL CLIPS/EXT SHEATHING ESTEVEN1 Approved APPROVED
06/14/2018 ROOF NAILING ESTEVEN1 Approved APPROVED
06/18/2018 ELECTRIC - CONSTRUCTION POWER BBENEDO1 Approved IVRS - Inspection :*
06/18/2018 ELECTRIC - CABLE DROP BBENEDO1 Approved IVRS - Inspection :*
06/19/2018 TEP CLEARANCE - AM BBENEDON Approved ECO
09/13/2018 MECHANICAL - INTERMEDIATE DFLORES2 Approved IVRS - Inspection :*
09/13/2018 PLUMBING - GAS PRESSURE TEST DFLORES2 Approved IVRS - Inspection :*
09/13/2018 PLUMBING - INTERMEDIATE DFLORES2 Approved IVRS - Inspection :*
09/13/2018 ELECTRIC - INTERMEDIATE DFLORES2 Approved IVRS - Inspection :*
09/13/2018 U VALUE FOR WINDOW DFLORES2 Approved IVRS - Inspection :*
09/13/2018 STUCCO MESH DFLORES2 Approved IVRS - Inspection :*
09/13/2018 FRAMING DFLORES2 Approved IVRS - Inspection :*
10/11/2018 SHEET ROCK NAILING DQUINN Approved
03/14/2019 REINFORCED MASONRY PRE-GROUT RCHANDLER Approved
05/28/2019 MECHANICAL - FINAL AKLEINSORGE Approved
05/28/2019 PLUMBING - FINAL AKLEINSORGE Approved
05/28/2019 PLUMBING - PROGRESS AKLEINSORGE Approved
05/28/2019 PLUMBING - ROOF DRAINS AKLEINSORGE Approved
05/28/2019 OUTDOOR LIGHTING FINAL AKLEINSORGE Approved
05/28/2019 ELECTRIC - FINAL AKLEINSORGE Approved
05/28/2019 BUILDING - FINAL AKLEINSORGE Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW
001_A2.0.TIF CONSTRPLANS VIEW
002_S1.1.10.TIF CONSTRPLANS VIEW
003_S3.1.10.TIF CONSTRPLANS VIEW
004_S3.2.10.TIF CONSTRPLANS VIEW
005_A3.0.TIF CONSTRPLANS VIEW
006_A6.1.TIF CONSTRPLANS VIEW
007_A7.0.TIF CONSTRPLANS VIEW
008_P1.0.TIF CONSTRPLANS VIEW
009_P2.0.TIF CONSTRPLANS VIEW
010_M1.0.TIF CONSTRPLANS VIEW
011_E1.0.TIF CONSTRPLANS VIEW