Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
COMMERCIAL ALTERATION
Address:
10 E BROADWAY BL
Address NEW:
10 E BROADWAY BL
Apply Date:
02/21/2018
Applicant:
N/A
Description:
TI: INTERIOR REMODEL OF ENTIRE 4 STORY BUILDING.
Contractors:
  • CANYON BUILDING AND DESIGN LLC *APA*

Permit Reviews

Permit Number - T18CM01321
Permit Status: Expired
Permit Description: TI: INTERIOR REMODEL OF ENTIRE 4 STORY BUILDING.
Start Date Submittal Complete Date Status  
02/21/2018 PLANS OK TO SUBMIT - COMM 02/21/2018 COMPLETED Review Details
02/22/2018 COMMERCIAL - TI 03/28/2018 COMPLETED Review Details
03/28/2018 RESUBMITTAL - TI ALL 05/04/2018 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T18CM01321
Permit Status: Expired
Permit Description: TI: INTERIOR REMODEL OF ENTIRE 4 STORY BUILDING.
Total Outstanding Activity Conditions - 2
Date Name
02/21/2018 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
03/14/2018 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.

Outstanding Inspections

Permit Status: Expired
Permit Number: T18CM01321
Permite Description: TI: INTERIOR REMODEL OF ENTIRE 4 STORY BUILDING.
Total Outstanding Inspections - 14
Last Inspection Date Description Inspector Results Comments
BUILDING ABOVE CEILING N/A Not Inspected
U VALUE FOR WINDOW N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
ELECTRIC - ABOVE CEILING N/A Not Inspected
OUTDOOR LIGHTING FINAL N/A Not Inspected
PLUMBING - ABOVE CEILING N/A Not Inspected
PLUMBING - GAS PRESSURE TEST N/A Not Inspected
MECHANICAL - INTERMEDIATE N/A Not Inspected
MECHANICAL - ABOVE CEILING N/A Not Inspected
MECHANICAL - FINAL N/A Not Inspected
FIRE SPKLR - FINAL N/A Not Inspected
FIRE - ALARM FINAL N/A Not Inspected
08/01/2018 ELECTRIC - INTERMEDIATE N/A Partial Approval exterior can lighting ok
11/14/2018 FRAMING N/A Partial Approval 1st floor walls ok to cover.

Completed Inspections

Permit Status: Expired
Permit Number: T18CM01321
Permit Description: TI: INTERIOR REMODEL OF ENTIRE 4 STORY BUILDING.
Total Completed Inspections - 2
Date Description Inspector Results Comments
08/01/2018 SHEET ROCK NAILING mramber1 Approved
08/01/2018 ELECTRIC - OUTDOOR LIGHTING mramber1 Approved

Documents

File Name Document Type  
001_T1.0.TIF CONSTRPLANS VIEW
002_A1.0.TIF CONSTRPLANS VIEW
003_A1.1.TIF CONSTRPLANS VIEW
004_A2.0.TIF CONSTRPLANS VIEW
005_A2.1.TIF CONSTRPLANS VIEW
006_A2.2.TIF CONSTRPLANS VIEW
007_A2.3.TIF CONSTRPLANS VIEW
008_A2.4.TIF CONSTRPLANS VIEW
009_A3.0.TIF CONSTRPLANS VIEW
010_A3.1.TIF CONSTRPLANS VIEW
011_A3.2.TIF CONSTRPLANS VIEW
012_A4.0.TIF CONSTRPLANS VIEW
013_A4.1.TIF CONSTRPLANS VIEW
014_A5.0.TIF CONSTRPLANS VIEW
015_A6.0.TIF CONSTRPLANS VIEW
016_A7.0.TIF CONSTRPLANS VIEW
017_A7.1.TIF CONSTRPLANS VIEW
018_A8.0.TIF CONSTRPLANS VIEW
019_A8.1.TIF CONSTRPLANS VIEW
020_S1.0.TIF CONSTRPLANS VIEW
021_S1.1.TIF.TIF CONSTRPLANS VIEW
022_S2.0.TIF.TIF CONSTRPLANS VIEW
023_M1.0.TIF.TIF CONSTRPLANS VIEW
024_M1.1.TIF.TIF CONSTRPLANS VIEW
025_M1.2.TIF.TIF CONSTRPLANS VIEW
026_M1.3.TIF.TIF CONSTRPLANS VIEW
027_M1.4.TIF.TIF CONSTRPLANS VIEW
028_M1.5.TIF.TIF CONSTRPLANS VIEW
029_M1.6.TIF.TIF CONSTRPLANS VIEW
030_M2.0.TIF.TIF CONSTRPLANS VIEW
031_M2.1.TIF.TIF CONSTRPLANS VIEW
032_M3.0.TIF.TIF CONSTRPLANS VIEW
033_M3.1.TIF.TIF CONSTRPLANS VIEW
034_M3.2.TIF.TIF CONSTRPLANS VIEW
035_M3.3.TIF.TIF CONSTRPLANS VIEW
036_M4.0.TIF.TIF CONSTRPLANS VIEW
037_P1.0.TIF.TIF CONSTRPLANS VIEW
038_P1.1.TIF.TIF CONSTRPLANS VIEW
039_P1.2.TIF.TIF CONSTRPLANS VIEW
040_P1.3.TIF.TIF CONSTRPLANS VIEW
041_P1.4.TIF.TIF CONSTRPLANS VIEW
042_P1.5.TIF.TIF CONSTRPLANS VIEW
043_P1.6.TIF.TIF CONSTRPLANS VIEW
044_P1.7.TIF.TIF CONSTRPLANS VIEW
045_P1.8.TIF.TIF CONSTRPLANS VIEW
046_P2.0.TIF.TIF CONSTRPLANS VIEW
047_P2.1.TIF.TIF CONSTRPLANS VIEW
048_P2.2.TIF.TIF CONSTRPLANS VIEW
049_P3.0.TIF.TIF CONSTRPLANS VIEW
050_P3.1.TIF.TIF CONSTRPLANS VIEW
051_P3.2.TIF.TIF CONSTRPLANS VIEW
052_P3.3.TIF.TIF CONSTRPLANS VIEW
053_E1.0.TIF.TIF CONSTRPLANS VIEW
054_E1.1.TIF.TIF CONSTRPLANS VIEW
055_E1.2.TIF.TIF CONSTRPLANS VIEW
056_E1.3.TIF.TIF CONSTRPLANS VIEW
057_E1.4TIF.TIF CONSTRPLANS VIEW
058_E2.0.TIF.TIF CONSTRPLANS VIEW
059_E2.1.TIF.TIF CONSTRPLANS VIEW
060_E2.2.TIF.TIF CONSTRPLANS VIEW
061_E2.3.TIF.TIF CONSTRPLANS VIEW
062_E2.4.TIF.TIF CONSTRPLANS VIEW
063_E2.5.TIF.TIF CONSTRPLANS VIEW
064_E3.0.TIF.TIF CONSTRPLANS VIEW
065_E3.1.TIF.TIF CONSTRPLANS VIEW
066_E3.2.TIF.TIF CONSTRPLANS VIEW
067_E4.0.TIF.TIF CONSTRPLANS VIEW
068_E4.1.TIF.TIF CONSTRPLANS VIEW
069_E4.2.TIF.TIF CONSTRPLANS VIEW
070_E4.3.TIF.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW
STRUCTURAL CALCS.PDF DOCUMENTS VIEW