Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Apply Date:
02/12/2018
Applicant:
KOWAL RICHARD
Description:
BEDROOM/RESTROOM ADDITION

Permit Reviews

Permit Number - T18CM01084
Permit Status: Expired
Permit Description: BEDROOM/RESTROOM ADDITION
Start Date Submittal Complete Date Status  
02/12/2018 RESIDENTIAL - BLDG/ZONING-WALKTHRU 03/19/2018 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T18CM01084
Permit Status: Expired
Permit Description: BEDROOM/RESTROOM ADDITION
Total Outstanding Activity Conditions - 1
Date Name
02/12/2018 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T18CM01084
Permite Description: BEDROOM/RESTROOM ADDITION
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
BUILDING - FINAL N/A Not Inspected
ELECTRIC - FINAL N/A Not Inspected
PLUMBING - FINAL N/A Not Inspected
MECHANICAL - FINAL N/A Not Inspected
11/07/2018 ELECTRIC - UFER N/A Partial Approval Stub up ok

Completed Inspections

Permit Status: Expired
Permit Number: T18CM01084
Permit Description: BEDROOM/RESTROOM ADDITION
Total Completed Inspections - 13
Date Description Inspector Results Comments
11/07/2018 PLUMBING - ROUGH, SOIL DQUINN Approved
11/07/2018 BUILDING PRE-SLAB DQUINN Approved
11/07/2018 EXCAVATION/LAYOUT REBAR & ZON DQUINN Approved
12/03/2018 ROOF NAILING RCHANDLER Approved
12/03/2018 EXT METAL CLIPS/EXT SHEATHING RCHANDLER Approved Need to clip existing bearing wall to new rafters.
OK to proceed elsewhere; reschedule with Intermediate.
01/23/2019 PLUMBING - INTERMEDIATE GWEST Approved Watercloset/toilet requires 30” clearspace from wall to shower pan as required by 2012 IRC R307.
Shower pan, all corner shower pan units being installed must meet the 2012 IRC requirements of IRC section of P2708.1 and Ex 2.
01/23/2019 MECHANICAL - INTERMEDIATE GWEST Approved
01/23/2019 PLUMBING - GAS PRESSURE TEST GWEST Approved
01/23/2019 ELECTRIC - INTERMEDIATE GWEST Approved
01/23/2019 U VALUE FOR WINDOW GWEST Approved
01/23/2019 STUCCO MESH GWEST Approved
01/23/2019 FRAMING GWEST Approved
01/24/2019 GAS CLEARANCE GWEST Approved

Documents

File Name Document Type  
001_A1.0.TIF CONSTRPLANS VIEW
002_A2.0.TIF CONSTRPLANS VIEW
003_A3.0.TIF CONSTRPLANS VIEW
004_A4.0.TIF CONSTRPLANS VIEW
005_A5.0.TIF CONSTRPLANS VIEW
006_A6.0.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW