Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T17CM08535
Permit Details
Apply Date:
11/15/2017
Applicant:
PEPPER VINER DEVELOPMENT CO II L L C ***APA***
Description:
SFR 1562CT T17-MOO53
Contractors:
- PEPPER VINER DEVELOPMENT CO II L L C ***APA***
Permit Reviews
Permit Number - T17CM08535
Permit Status: Final
Permit Description: SFR 1562CT T17-MOO53
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/15/2017 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 11/15/2017 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T17CM08535
Permit Status: Final
Permit Description: SFR 1562CT T17-MOO53
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/15/2017 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T17CM08535
Permit Description: SFR 1562CT T17-MOO53
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/01/2017 | PLUMBING - YARD WTR LINE/TEST | TVALENC1 | Approved | IVRS - Inspection :* |
| 12/01/2017 | PLUMBING - ROUGH, SOIL | TVALENC1 | Approved | IVRS - Inspection :* |
| 12/08/2017 | BUILDING PRE-SLAB | TVALENC1 | Approved | IVRS - Inspection :* |
| 12/08/2017 | EXCAVATION/LAYOUT REBAR & ZON | TVALENC1 | Approved | IVRS - Inspection :* |
| 01/02/2018 | ROOF NAILING | TVALENC1 | Approved | IVRS - Inspection :* |
| 01/02/2018 | EXT METAL CLIPS/EXT SHEATHING | TVALENC1 | Approved | IVRS - Inspection :* |
| 01/16/2018 | ELECTRIC - CONSTRUCTION POWER | rbaldwin | Approved | |
| 01/16/2018 | ELECTRIC - CABLE DROP | rbaldwin | Approved | |
| 01/17/2018 | TEP CLEARANCE - AM | RBALDWIN | Approved | TEC |
| 02/09/2018 | PLUMBING - SEWER HCS CONNECT | TVALENC1 | Approved | IVRS - Inspection :* |
| 02/09/2018 | PLUMBING - GAS PRESSURE TEST | TVALENC1 | Approved | IVRS - Inspection :* |
| 02/09/2018 | FRAMING | TVALENC1 | Approved | IVRS - Inspection :* |
| 02/09/2018 | MECHANICAL - INTERMEDIATE | MHASSAN1 | Approved | |
| 02/09/2018 | PLUMBING - GAS PRESSURE TEST | MHASSAN1 | Approved | GAUGE NOT HOLDING AIR |
| 02/09/2018 | PLUMBING - INTERMEDIATE | MHASSAN1 | Approved | |
| 02/09/2018 | ELECTRIC - INTERMEDIATE | MHASSAN1 | Approved | |
| 02/09/2018 | ELECTRIC - UFER | MHASSAN1 | Approved | |
| 02/09/2018 | U VALUE FOR WINDOW | MHASSAN1 | Approved | |
| 02/09/2018 | STUCCO MESH | MHASSAN1 | Approved | |
| 02/09/2018 | FRAMING | MHASSAN1 | Approved | QUESTION ON WHERE THE H2.5'S ARE ON THE PATIO, HAVE FRAMER CHECK DETAIL 11 ON SD3.1 |
| 02/26/2018 | SHEET ROCK NAILING | TVALENC1 | Approved | IVRS - Inspection :* |
| 04/20/2018 | MECHANICAL - FINAL | TVALENC1 | Approved | IVRS - Inspection :* |
| 04/20/2018 | PLUMBING - FINAL | TVALENC1 | Approved | IVRS - Inspection :* |
| 04/20/2018 | OUTDOOR LIGHTING FINAL | TVALENC1 | Approved | IVRS - Inspection :* |
| 04/20/2018 | ELECTRIC - FINAL | TVALENC1 | Approved | IVRS - Inspection :* |
| 04/20/2018 | ELECTRIC - UNDERGROUND | TVALENC1 | Approved | IVRS - Inspection :* |
| 04/20/2018 | BUILDING - FINAL | TVALENC1 | Approved | IVRS - Inspection :* |