Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Apply Date:
10/17/2017
Applicant:
Tom Wellman
Description:
BEDROOM/BATHROOM/sleeping quarters AND PORCH ADDITION

Permit Reviews

Permit Number - T17CM07820
Permit Status: Expired
Permit Description: BEDROOM/BATHROOM/sleeping quarters AND PORCH ADDITION
Start Date Submittal Complete Date Status  
03/01/2018 REVISION - - 1ST 03/01/2018 COMPLETED Review Details
10/17/2017 RESIDENTIAL - BLDG/ZONING-WALKTHRU 10/17/2017 COMPLETED Review Details
10/17/2017 RESIDENTIAL - BLDG/WWM 11/27/2017 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T17CM07820
Permit Status: Expired
Permit Description: BEDROOM/BATHROOM/sleeping quarters AND PORCH ADDITION
Total Outstanding Activity Conditions - 1
Date Name
10/17/2017 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Expired
Permit Number: T17CM07820
Permit Description: BEDROOM/BATHROOM/sleeping quarters AND PORCH ADDITION
Total Completed Inspections - 17
Date Description Inspector Results Comments
03/15/2018 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 03/15/2018; Status: Approved; Inspector: NORTH; Comment: Entered by BNORTH1 - }
08/03/2018 COT - RSBU - Roof Nailing Passed {Activity date: 08/03/2018; Status: Approved; Inspector: MHASSAN1; Comment: Entered by MHASSAN1 - }
08/03/2018 COT - RSPL - Rough Soil Passed {Activity date: 08/03/2018; Status: Approved; Inspector: MHASSAN1; Comment: Entered by MHASSAN1 - }
08/08/2018 COT - RSBU - Sustainability Passed {Activity date: 08/08/2018; Status: Approved; Inspector: TVALENC1; Comment: Entered by TVALENC1 - IVRS - Inspection :*}
08/09/2018 RSEL - Electrical Progress Passed {Activity date: 08/09/2018; Status: Approved; Inspector: TVALENC1; Comment: Entered by TVALENC1 - IVRS - Inspection :*}
08/09/2018 RSME - Mechanical Progress Passed {Activity date: 08/09/2018; Status: Approved; Inspector: TVALENC1; Comment: Entered by TVALENC1 - IVRS - Inspection :*}
08/10/2018 COT - LCPL - Plumbing Intermediate Passed {Activity date: 08/10/2018; Status: Approved; Inspector: TVALENC1; Comment: Entered by TVALENC1 - IVRS - Inspection :*} ; {Activity date: 08/09/2018; Status: Denied; Inspector: TVALENC1; Comment: Entered by TVALENC1 - 1- SHALL PROVIDE A WATER TEST ON DWV SYSTEM.
2- SHALL PROVIDE THE REQUIRED SHIELD PLATES FOR THE ABS PROTECTION AT SOLE AND TOP PLATES.
}
08/10/2018 COT - RSEL - Service Upgrade Passed {Activity date: 08/10/2018; Status: Approved; Inspector: TVALENC1; Comment: Entered by TVALENC1 - IVRS - Inspection :*} ; {Activity date: 08/09/2018; Status: Denied; Inspector: TVALENC1; Comment: Entered by TVALENC1 - IVRS - Inspection :
See detailed listing on site.| 999


*} ; {Activity date: 08/09/2018; Status: Not ready for Inspection; Inspector: TVALENC1; Comment: Entered by TVALENC1 - IVRS - Inspection :*
1- SHALL LAND ALLCONDUCTORS AND CIRCUIT BREAKERS.
2- SHALL SEAL ALL TOP PLATE PENETRATIONS WITH FIRE RATED FOAM OR CAULK.}
08/13/2018 BULD - Electrical Clearance Passed {Activity date: 08/13/2018; Status: Approved; Inspector: TVALENCIA; Comment: Entered by AMONTIJ2 - INCR}
03/26/2019 COT - RSME - Mechanical Final Passed {Activity date: 03/26/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - }
03/26/2019 COT - LCBU - Framing Passed {Activity date: 03/26/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } ; {Activity date: 08/03/2018; Status: Not ready for Inspection; Inspector: MHASSAN1; Comment: Entered by MHASSAN1 - AFTER INTERMEDIATES, OR PREFERRABLY AT THE SAME TIME AS INTERMEDIATES.}
03/26/2019 RSBU - Building Final Passed {Activity date: 03/26/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - }
03/26/2019 COT - RSBU - Stem Wall/Retaining Wall Passed {Activity date: 03/26/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - }
03/26/2019 COT - RSEL - Outdoor Lighting Passed {Activity date: 03/26/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - }
03/26/2019 COT - RSPL - Plumbing Final Passed {Activity date: 03/26/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - }
03/26/2019 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed {Activity date: 03/26/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - } ; {Activity date: 08/03/2018; Status: Partial Approval; Inspector: MHASSAN1; Comment: Entered by MHASSAN1 - NEED H2.5 CLIPS INSTALLED PER DETAIL 1 AND 2 ON ROOF FRAMING PAGE}
03/26/2019 COT - RSEL - Electrical Final Passed {Activity date: 03/26/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by CBELL1 - }

Documents

File Name Document Type  
001_A0.TIF CONSTRPLANS VIEW
002_A1.TIF CONSTRPLANS VIEW
003_A2.TIF CONSTRPLANS VIEW
004_S1.TIF CONSTRPLANS VIEW
005_X1.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW