Permit Reviews
Permit Number - T17CM07586
Permit Status: C of o
Permit Description: APARTMENTS
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/23/2018 | REVISION - - 1ST | 05/24/2018 | COMPLETED |
06/28/2018 | REVISION - - 2ND | 06/28/2018 | COMPLETED |
10/06/2017 | PLANS OK TO SUBMIT - COMM | 10/06/2017 | COMPLETED |
10/12/2017 | COMMERCIAL - NEW | 11/15/2017 | COMPLETED |
11/14/2018 | REVISION - - 3RD | 11/14/2018 | COMPLETED |
11/15/2017 | RESUBMITTAL | 12/15/2017 | COMPLETED |
12/15/2017 | RESUBMITTAL | 05/04/2018 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T17CM07586
Permit Status: C of o
Permit Description: APARTMENTS
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/06/2017 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T17CM07586
Permit Description: APARTMENTS
Total Completed Inspections - 44
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/01/2017 | FIRE SPKLR - FINAL | RHERNANDEZ | Approved | P2I MAY BE DELETED WHEN THE ROOF/FLOOR TRUSS DESIGN CALCULATIONS AND DRAWINGS HAVE BEEN REVIEWED AND APPROVED. |
11/27/2017 | MECHANICAL - FINAL | RSHERRY | Approved | REVIEW OF AIR BALANCE REPORT REQUIRED |
12/19/2017 | PLUMBING - FINAL | RSHERRY | Approved | WATER CHLORINATION REPORT REQUIRED |
07/11/2018 | ELECTRIC - TEMPORARY POLE | BBENEDO1 | Approved | IVRS - Inspection :* |
07/12/2018 | TEP CLEARANCE - AM | BBENEDON | Approved | TMPP |
09/13/2018 | PLUMBING - ROUGH, SOIL | BJONES | Approved | Building two unit 2105 2106 building three unit 3101 through 3104 and units 3201- through 3204 RFI to architect for building number revision |
10/12/2018 | PLUMBING - PROGRESS | BJONES | Approved | building number one includes a backwater valve |
10/12/2018 | PLUMBING - PROGRESS | BJONES | Approved | |
10/12/2018 | SITE - SEWER | BJONES | Approved | building number one includes a backwater valve |
11/21/2018 | ENGINEERING - FINAL | BBENEDON | Approved | Schedule inspections 4 site work from development package permit, dp1 60241 |
11/28/2018 | ELECTRIC - UFER | TVALENCIA | Approved | 20 feet of horizontal steel ufer provided. |
11/28/2018 | EXCAVATION/LAYOUT REBAR & ZON | TVALENCIA | Approved | 1- Steel reinforcement provided in footing for the West stem and retaining wall. |
11/28/2018 | ELECTRIC - UFER | TVALENCIA | Approved | 1- 20 feet of horizontal steel Ufer Conductor provided. |
11/28/2018 | EXCAVATION/LAYOUT REBAR & ZON | TVALENCIA | Approved | 1- Steel reinforcement provided in footing for the West stem and retaining wall. |
12/05/2018 | STEM WALL/RETAINING WALL | ESTEVENS | Approved | West side retaining wall and north west corner, south west wall from the corner to approximately 2/3 the length of the wall |
12/11/2018 | ELECTRIC - UNDERGROUND | ESTEVENS | Approved | Service from building one to community center. |
12/11/2018 | ELECTRIC - INTERMEDIATE | ESTEVENS | Approved | Contractor entered the incorrect code |
01/31/2019 | BUILDING PRE-SLAB | TVALENCIA | Approved | |
03/18/2019 | ROOF NAILING | TVALENCIA | Approved | |
03/18/2019 | EXT METAL CLIPS/EXT SHEATHING | TVALENCIA | Approved | |
04/10/2019 | STUCCO MESH | TVALENCIA | Approved | |
04/22/2019 | PLUMBING - INTERMEDIATE | TVALENCIA | Approved | |
04/25/2019 | MECHANICAL - ABOVE CEILING | TVALENCIA | Approved | |
04/25/2019 | MECHANICAL - INTERMEDIATE | TVALENCIA | Approved | |
04/25/2019 | FIREWALL/FIREBARRIER/FIRESTOP | TVALENCIA | Approved | |
04/25/2019 | BUILDING ABOVE CEILING | TVALENCIA | Approved | |
05/06/2019 | ELECTRIC - CONSTRUCTION POWER | TVALENCIA | Approved | Clear electric eco |
05/06/2019 | ELECTRIC - TEMPORARY SERVICE | TVALENCIA | Approved | |
05/24/2019 | ELECTRIC - PROGRESS | TVALENCIA | Approved | |
05/24/2019 | SHEET ROCK NAILING | TVALENCIA | Approved | |
05/24/2019 | FRAMING | TVALENCIA | Approved | |
06/06/2019 | TEP CLEARANCE - PM | BSTEVENS | Approved | CODE ECO |
08/15/2019 | FIRE - FINAL | CBASALDUA | Approved | |
08/15/2019 | FIRE - ALARM FINAL | CBASALDUA | Approved | |
08/15/2019 | PLUMBING - BACK WATER VALVE | DQUINN | Approved | |
08/15/2019 | PLUMBING - YARD WTR LINE/TEST | DQUINN | Approved | |
08/15/2019 | ELECTRIC - ABOVE CEILING | DQUINN | Approved | |
08/15/2019 | BUILDING - PROGRESS | DQUINN | Approved | |
08/15/2019 | U VALUE FOR WINDOW | DQUINN | Approved | |
08/15/2019 | ELECTRIC - FINAL | DQUINN | Approved | |
08/15/2019 | OUTDOOR LIGHTING FINAL | DQUINN | Approved | |
08/15/2019 | ELECTRIC - OUTDOOR LIGHTING | DQUINN | Approved | |
08/21/2019 | CERTIFICATE OF OCCUPANCY | DQUINN | Approved | |
08/21/2019 | BUILDING - FINAL | RSHERRY | Approved |