Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/27/2017 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 09/27/2017 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T17CM07383
Permit Status: Final
Permit Description: SFR LENN357516 T16-M0043
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/27/2017 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T17CM07383
Permit Description: SFR LENN357516 T16-M0043
Total Completed Inspections - 27
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/17/2017 | PLUMBING - SEWER HCS CONNECT | BBENEDO1 | Approved | IVRS - Inspection :* |
10/17/2017 | PLUMBING - YARD WTR LINE/TEST | BBENEDO1 | Approved | IVRS - Inspection :* |
10/17/2017 | PLUMBING - ROUGH, SOIL | BBENEDO1 | Approved | IVRS - Inspection :* |
10/26/2017 | ELECTRIC - UNDERGROUND | BBENEDO1 | Approved | IVRS - Inspection :* |
10/26/2017 | ELECTRIC - UFER | BBENEDO1 | Approved | IVRS - Inspection :* |
10/26/2017 | BUILDING PRE-SLAB | BBENEDO1 | Approved | IVRS - Inspection :* |
10/26/2017 | EXCAVATION/LAYOUT REBAR & ZON | BBENEDO1 | Approved | IVRS - Inspection :* |
11/16/2017 | ROOF NAILING | BBENEDO1 | Approved | IVRS - Inspection :* |
11/16/2017 | EXT METAL CLIPS/EXT SHEATHING | BBENEDO1 | Approved | IVRS - Inspection :* |
11/24/2017 | ELECTRIC - CONSTRUCTION POWER | BBENEDO1 | Approved | IVRS - Inspection :* |
11/24/2017 | ELECTRIC - CABLE DROP | BBENEDO1 | Approved | IVRS - Inspection :* |
12/12/2017 | MECHANICAL - INTERMEDIATE | rbaldwin | Approved | |
12/12/2017 | PLUMBING - GAS PRESSURE TEST | rbaldwin | Approved | |
12/12/2017 | PLUMBING - INTERMEDIATE | rbaldwin | Approved | |
12/12/2017 | ELECTRIC - INTERMEDIATE | rbaldwin | Approved | |
12/12/2017 | U VALUE FOR WINDOW | rbaldwin | Approved | |
12/12/2017 | STUCCO MESH | rbaldwin | Approved | 1 install diamond mesh on horizontal patio beams 12" or greater 2 complete popout after window install on east and west sides |
12/12/2017 | FRAMING | rbaldwin | Approved | 1 shim and strap let ins 2provide min 30" CLEARANCE AT ATTIC ACCESS 3 shim bearing headers throughout 4 let ins in garage only allowed to span 3 studs on a bearing wall 5 nail gable braces per detail 7sd3 6 provide truss calcs |
01/09/2018 | SHEET ROCK NAILING | BBENEDO1 | Approved | IVRS - Inspection :* |
02/16/2018 | GAS CLEARANCE | RGREENE | Approved | |
02/16/2018 | PLUMBING - PROGRESS | RGREENE1 | Approved | GAS METER CLEARANCE |
02/16/2018 | PLUMBING - PROGRESS | IVR USER | Approved | IVRS - RI canceled |
02/23/2018 | MECHANICAL - FINAL | DFLORES2 | Approved | |
02/23/2018 | PLUMBING - FINAL | DFLORES2 | Approved | |
02/23/2018 | OUTDOOR LIGHTING FINAL | DFLORES2 | Approved | |
02/23/2018 | ELECTRIC - FINAL | DFLORES2 | Approved | |
02/23/2018 | BUILDING - FINAL | DFLORES2 | Approved |