Permit: T17CM06828
Permit Details
Apply Date:
09/06/2017
Applicant:
POSTER, CHARLES MARCUS
Description:
SFR ODENB1729 T16-M0058
Architects:
- POSTER, CHARLES MARCUS
Contractors:
- ODEN CONSTRUCTION INC
Permit Reviews
Permit Number - T17CM06828
Permit Status: C of o
Permit Description: SFR ODENB1729 T16-M0058
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/06/2017 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 09/07/2017 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T17CM06828
Permit Status: C of o
Permit Description: SFR ODENB1729 T16-M0058
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/06/2017 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T17CM06828
Permit Description: SFR ODENB1729 T16-M0058
Total Completed Inspections - 35
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/15/2017 | PLUMBING - ROUGH, SOIL | NORTH | Approved | |
| 09/20/2017 | PLUMBING - PRE SLAB | DQUINN | Approved | |
| 09/20/2017 | ELECTRIC - UFER | DQUINN | Approved | |
| 09/20/2017 | ELECTRIC - UNDERGROUND | DQUINN | Approved | |
| 09/20/2017 | BUILDING PRE-SLAB | DQUINN | Approved | |
| 09/20/2017 | EXCAVATION/LAYOUT REBAR & ZON | DQUINN | Approved | |
| 01/30/2018 | BUILDING ABOVE CEILING | IVR USER | Approved | IVRS - AP canceled |
| 02/01/2018 | ROOF NAILING | mramber1 | Approved | |
| 02/01/2018 | BUILDING - PROGRESS | mramber1 | Approved | |
| 02/01/2018 | ELECTRIC - ABOVE CEILING | mramber1 | Approved | |
| 02/01/2018 | ELECTRIC - PROGRESS | mramber1 | Approved | |
| 02/01/2018 | PLUMBING - ABOVE CEILING | mramber1 | Approved | |
| 02/01/2018 | PLUMBING - GAS PRESSURE TEST | mramber1 | Approved | |
| 02/01/2018 | PLUMBING - PROGRESS | mramber1 | Approved | |
| 02/01/2018 | MECHANICAL - ABOVE CEILING | mramber1 | Approved | |
| 02/01/2018 | MECHANICAL - PROGRESS | mramber1 | Approved | |
| 02/06/2018 | MECHANICAL - INTERMEDIATE | rbaldwin | Approved | |
| 02/06/2018 | PLUMBING - INTERMEDIATE | rbaldwin | Approved | |
| 02/06/2018 | ELECTRIC - INTERMEDIATE | rbaldwin | Approved | |
| 02/06/2018 | FRAMING | rbaldwin | Approved | |
| 03/08/2018 | U VALUE FOR WINDOW | RCAMACHO | Approved | |
| 03/08/2018 | STUCCO MESH | RCAMACHO | Approved | |
| 05/02/2018 | ELECTRIC - CONSTRUCTION POWER | mramber1 | Approved | |
| 05/03/2018 | TEP CLEARANCE - AM | MRAMBER | Approved | ECO |
| 07/24/2018 | PLUMBING - SEWER HCS CONNECT | GWest | Approved | |
| 07/24/2018 | PLUMBING - YARD WTR LINE/TEST | GWest | Approved | |
| 07/24/2018 | PLUMBING - ROOF DRAINS | GWest | Approved | |
| 09/17/2018 | ELECTRIC - OUTDOOR LIGHTING | RCAMACHO | Approved | Anti tilt stove Complete b vent installation water heater |
| 12/19/2018 | BUILDING - FINAL | ESTEVENS | Approved | No house number, patch post tension holes, carbon monoxide detector required, no Certs. |
| 12/19/2018 | PLUMBING - FINAL | ESTEVENS | Approved | Caulk around toilet, install dishwasher |
| 12/19/2018 | MECHANICAL - FINAL | ESTEVENS | Approved | |
| 12/19/2018 | PLUMBING - GAS PRESS TEST FNL | ESTEVENS | Approved | |
| 12/19/2018 | ELECTRIC - FINAL | ESTEVENS | Approved | Outside outlets have no power, two appliance circuits are required in kitchen. |
| 12/21/2018 | GAS CLEARANCE | ESTEVENS | Approved | |
| 01/18/2019 | ELECTRIC - SERVICE UPGRADE | DMCCARTHY | Approved | approved upon 2090 approval from DMCCARTHY |