Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T17CM05162
Permit Details
Apply Date:
07/05/2017
Applicant:
MERITAGE HOMES
Description:
SFR PLAN2740 T16-M0009
Contractors:
- MERITAGE HOMES
- MERITAGE HOMES CONSTRUCTION INC *** APA***
Permit Reviews
Permit Number - T17CM05162
Permit Status: Final
Permit Description: SFR PLAN2740 T16-M0009
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/05/2017 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/05/2017 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T17CM05162
Permit Status: Final
Permit Description: SFR PLAN2740 T16-M0009
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/05/2017 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T17CM05162
Permit Description: SFR PLAN2740 T16-M0009
Total Completed Inspections - 28
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/20/2017 | SITE - SEWER | BBENEDON | Approved | |
10/20/2017 | PLUMBING - PRE SLAB | BBENEDON | Approved | |
10/20/2017 | ELECTRIC - UFER | BBENEDON | Approved | |
10/20/2017 | ROOF NAILING | BBENEDON | Approved | |
10/20/2017 | EXT METAL CLIPS/EXT SHEATHING | BBENEDON | Approved | |
10/20/2017 | ELECTRIC - UNDERGROUND | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | ELECTRIC - UFER | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | BUILDING PRE-SLAB | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | EXCAVATION/LAYOUT REBAR & ZON | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | U VALUE FOR WINDOW | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | STUCCO MESH | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | PLUMBING - SEWER HCS CONNECT | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | PLUMBING - YARD WTR LINE/TEST | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | PLUMBING - ROUGH, SOIL | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | MECHANICAL - INTERMEDIATE | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | PLUMBING - GAS PRESSURE TEST | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | PLUMBING - INTERMEDIATE | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | ELECTRIC - INTERMEDIATE | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | FRAMING | BBENEDO1 | Approved | IVRS - Inspection :* |
10/20/2017 | ELECTRIC - CABLE DROP | BBENEDO1 | Approved | IVRS - Inspection :* |
10/24/2017 | TEP CLEARANCE - AM | BBENEDON | Approved | ECO |
10/25/2017 | SHEET ROCK NAILING | NORTH | Approved | |
12/07/2017 | PLUMBING - GAS PRESS TEST FNL | BBENEDO1 | Approved | IVRS - Inspection :* |
12/07/2017 | MECHANICAL - FINAL | BBENEDO1 | Approved | IVRS - Inspection :* |
12/07/2017 | PLUMBING - FINAL | BBENEDO1 | Approved | IVRS - Inspection :* |
12/07/2017 | ELECTRIC - FINAL | BBENEDO1 | Approved | IVRS - Inspection :* |
12/07/2017 | BUILDING - FINAL | BBENEDO1 | Approved | IVRS - Inspection :* |
12/08/2017 | GAS CLEARANCE | BBENEDON | Approved |