Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL ALTERATION
Apply Date:
06/30/2017
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
TI: OFFICE
Architects:
  • LEWIS, JEFFREY
Contractors:
  • EPSTEIN CONSTRUCTION L L C

Permit Reviews

Permit Number - T17CM05095
Permit Status: Final
Permit Description: TI: OFFICE
Start Date Submittal Complete Date Status  
06/30/2017 COMMERCIAL - TI 08/11/2017 COMPLETED Review Details
08/11/2017 COMMERCIAL - TI 08/29/2017 COMPLETED Review Details
08/29/2017 RESUBMITTAL 10/12/2018 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T17CM05095
Permit Status: Final
Permit Description: TI: OFFICE
Total Outstanding Activity Conditions - 1
Date Name
06/30/2017 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T17CM05095
Permit Description: TI: OFFICE
Total Completed Inspections - 14
Date Description Inspector Results Comments
11/20/2018 SHEET ROCK NAILING DMUNIZ Approved 103 CORRIDOR OK TO ROCK.
ENTRY TO FILE ROOM OK TO ROCK.
11/20/2018 ELECTRIC - INTERMEDIATE DMUNIZ Approved
11/20/2018 FRAMING DMUNIZ Approved
01/08/2019 MECHANICAL - ABOVE CEILING RCAMACHO Approved
01/08/2019 ELECTRIC - ABOVE CEILING RCAMACHO Approved
01/08/2019 BUILDING ABOVE CEILING RCAMACHO Approved
01/31/2019 BUILDING - FINAL DQUINN Approved
01/31/2019 ENGINEERING - FINAL RLEDONNE Approved
01/31/2019 FIRE - FINAL CBASALDUA Approved
01/31/2019 FIRE SPKLR - FINAL CBASALDUA Approved
02/01/2019 BUILDING - PROGRESS DQUINN Approved approved upon 4090 approval from DQUINN
02/01/2019 MECHANICAL - INTERMEDIATE DQUINN Approved approved upon 4090 approval from DQUINN
02/01/2019 MECHANICAL - FINAL DQUINN Approved
02/01/2019 ELECTRIC - FINAL DQUINN Approved

Documents

File Name Document Type  
None LETTER OF COMPLETION VIEW
001_G000.TIF CONSTRPLANS VIEW
002_G001.TIF CONSTRPLANS VIEW
003_G010.TIF CONSTRPLANS VIEW
004_AD01.TIF CONSTRPLANS VIEW
005_A101.TIF CONSTRPLANS VIEW
006_A102.TIF CONSTRPLANS VIEW
007_A103.TIF CONSTRPLANS VIEW
008_A104.TIF CONSTRPLANS VIEW
009_A110.TIF CONSTRPLANS VIEW
010_A111.TIF CONSTRPLANS VIEW
011_A320.TIF CONSTRPLANS VIEW
012_A500.TIF CONSTRPLANS VIEW
013_M101.TIF CONSTRPLANS VIEW
014_M102.TIF CONSTRPLANS VIEW
015_E000.TIF CONSTRPLANS VIEW
016_E101.TIF CONSTRPLANS VIEW
017_E102.TIF CONSTRPLANS VIEW
018_E201.TIF CONSTRPLANS VIEW
019_E202.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW