Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
L of c
Type:
COMMERCIAL ALTERATION
Apply Date:
06/15/2017
Applicant:
JOSE L CEJA
Description:
TI: PET SHOP
Architects:
  • JOSE L CEJA
Contractors:
  • COMMERCIAL CARPET CLEANING INC

Permit Reviews

Permit Number - T17CM04655
Permit Status: L of c
Permit Description: TI: PET SHOP
Start Date Submittal Complete Date Status  
06/15/2017 COMMERCIAL - TI 06/16/2017 COMPLETED Review Details
08/15/2017 COMMERCIAL - TI 10/11/2017 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T17CM04655
Permit Status: L of c
Permit Description: TI: PET SHOP
Total Outstanding Activity Conditions - 1
Date Name
06/15/2017 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: L of c
Permit Number: T17CM04655
Permit Description: TI: PET SHOP
Total Completed Inspections - 17
Date Description Inspector Results Comments
09/13/2017 FRAMING TVALENC1 Approved
09/15/2017 ELECTRIC - INTERMEDIATE TVALENC1 Approved
10/02/2017 PLUMBING - ABOVE CEILING TVALENC1 Approved IVRS - Inspection :*
10/02/2017 PLUMBING - INTERMEDIATE TVALENC1 Approved IVRS - Inspection :*
10/02/2017 MECHANICAL - ABOVE CEILING TVALENC1 Approved IVRS - Inspection :*
10/02/2017 MECHANICAL - INTERMEDIATE TVALENC1 Approved IVRS - Inspection :*
10/05/2017 PLUMBING - ROUGH, SOIL TVALENC1 Approved
10/05/2017 ELECTRIC - ABOVE CEILING TVALENC1 Approved
10/05/2017 BUILDING - PROGRESS TVALENC1 Approved IVRS - Inspection :*
10/05/2017 PLUMBING - PROGRESS TVALENC1 Approved IVRS - Inspection :*
10/05/2017 MECHANICAL - FINAL TVALENC1 Approved IVRS - Inspection :*
10/05/2017 PLUMBING - FINAL TVALENC1 Approved IVRS - Inspection :*
10/05/2017 ELECTRIC - FINAL TVALENC1 Approved IVRS - Inspection :*
10/05/2017 FIRE - FINAL jvincent Approved
10/05/2017 FIRE SPKLR - FINAL jvincent Approved
10/13/2017 ENGINEERING - FINAL RLEDON Approved ADA PARKING AREAS AND RAMPS ARE OVER 2% SLOPES NOT INSTALLED PER ICC. PLANS AND PERMITS ARE FOR TI INSIDE BUILDING.
10/13/2017 BUILDING - FINAL RSHERRY Approved REVIEW OF AIR BALANCE REPORT COMPLETE

Documents

File Name Document Type  
None LETTER OF COMPLETION VIEW
001_A1.0.TIF CONSTRPLANS VIEW
002_D1.0.TIF CONSTRPLANS VIEW
003_A2.0.TIF CONSTRPLANS VIEW
004_A3.0.TIF CONSTRPLANS VIEW
005_P0.1.TIF CONSTRPLANS VIEW
006_P1.0.TIF CONSTRPLANS VIEW
007_M0.1.TIF CONSTRPLANS VIEW
008_M1.0.TIF CONSTRPLANS VIEW
009_E1.TIF CONSTRPLANS VIEW
010_E2.TIF CONSTRPLANS VIEW
011_E3.TIF CONSTRPLANS VIEW
012_E4.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW