Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T17CM02280
Permit Details
Apply Date:
03/22/2017
Applicant:
RICHMOND AMERICAN CONSTRUCTION INC
Description:
SFR RICHT21S13 T13-M0005
Contractors:
- RICHMOND AMERICAN CONSTRUCTION INC
Permit Reviews
Permit Number - T17CM02280
Permit Status: Expired
Permit Description: SFR RICHT21S13 T13-M0005
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/22/2017 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 03/22/2017 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T17CM02280
Permit Status: Expired
Permit Description: SFR RICHT21S13 T13-M0005
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
03/22/2017 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
03/22/2017 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
03/22/2017 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
03/22/2017 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T17CM02280
Permit Description: SFR RICHT21S13 T13-M0005
Total Completed Inspections - 26
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/06/2017 | PLUMBING - ROUGH, SOIL | BNORTH | Approved | |
04/17/2017 | PLUMBING - SEWER HCS CONNECT | bbenedon | Approved | |
04/17/2017 | BUILDING PRE-SLAB | bbenedon | Approved | |
04/17/2017 | EXCAVATION/LAYOUT REBAR & ZON | bbenedon | Approved | |
04/18/2017 | PLUMBING - YARD WTR LINE/TEST | bbenedon | Approved | |
04/26/2017 | ROOF NAILING | bbenedon | Approved | |
04/26/2017 | EXT METAL CLIPS/EXT SHEATHING | bbenedon | Approved | |
05/24/2017 | TEP CLEARANCE - AM | BBENEDON | Approved | ECO |
05/24/2017 | U VALUE FOR WINDOW | BBENEDO1 | Approved | IVRS - Inspection :* |
05/24/2017 | ELECTRIC - TEMPORARY SERVICE | BBENEDO1 | Approved | IVRS - Inspection :* |
05/24/2017 | ELECTRIC - UFER | BBENEDO1 | Approved | IVRS - Inspection :* |
05/24/2017 | ELECTRIC - CABLE DROP | BBENEDO1 | Approved | IVRS - Inspection :* |
05/24/2017 | MECHANICAL - INTERMEDIATE | BBENEDO1 | Approved | IVRS - Inspection :* |
05/24/2017 | PLUMBING - GAS PRESSURE TEST | BBENEDO1 | Approved | IVRS - Inspection :* |
05/24/2017 | PLUMBING - INTERMEDIATE | BBENEDO1 | Approved | IVRS - Inspection :* |
05/24/2017 | ELECTRIC - INTERMEDIATE | BBENEDO1 | Approved | IVRS - Inspection :* |
05/24/2017 | FRAMING | BBENEDO1 | Approved | IVRS - Inspection :* |
05/25/2017 | STUCCO MESH | bbenedon | Approved | |
06/02/2017 | SHEET ROCK NAILING | BBENEDO1 | Approved | IVRS - Inspection :* |
07/06/2017 | MECHANICAL - FINAL | bbenedon | Approved | |
07/06/2017 | PLUMBING - GAS PRESS TEST FNL | bbenedon | Approved | |
07/06/2017 | OUTDOOR LIGHTING FINAL | bbenedon | Approved | |
07/07/2017 | GAS CLEARANCE | BENEDON | Approved | |
07/12/2017 | PLUMBING - FINAL | BBENEDO1 | Approved | IVRS - Inspection :* |
07/12/2017 | ELECTRIC - FINAL | BBENEDO1 | Approved | IVRS - Inspection :* |
07/12/2017 | BUILDING - FINAL | BBENEDO1 | Approved | IVRS - Inspection :* |