Permit: T17CM02103
Permit Details
Apply Date:
03/15/2017
Applicant:
STURGEON ELECTRIC COMPANY INC ,
Description:
OFFICE
Contractors:
- STURGEON ELECTRIC COMPANY INC ,
Permit Reviews
Permit Number - T17CM02103
Permit Status: C of o
Permit Description: OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/15/2017 | PLANS OK TO SUBMIT - COMM | 03/15/2017 | COMPLETED |
| 03/22/2017 | COMMERCIAL - TI | 04/26/2017 | COMPLETED |
| 05/05/2017 | RESUBMITTAL - TI ALL | 06/08/2017 | COMPLETED |
| 06/29/2017 | RESUBMITTAL - TI ALL | 08/25/2017 | COMPLETED |
| 08/25/2017 | RESUBMITTAL - TI ALL | 09/07/2017 | COMPLETED |
| 09/07/2017 | RESUBMITTAL | 09/15/2017 | COMPLETED |
| 12/19/2017 | REVISION - - 1ST | 01/10/2018 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T17CM02103
Permit Description: OFFICE
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/12/2017 | PLUMBING - ROUGH, SOIL | mramber1 | Approved | |
| 10/23/2017 | FRAMING | mramber1 | Approved | red iron in demising wall mid span |
| 10/30/2017 | SHEET ROCK NAILING | DQUINN | Approved | |
| 11/29/2017 | BUILDING ABOVE CEILING | mramber1 | Approved | |
| 11/29/2017 | BUILDING - PROGRESS | mramber1 | Approved | |
| 11/29/2017 | ELECTRIC - UNDERGROUND | mramber1 | Approved | |
| 11/29/2017 | ELECTRIC - ABOVE CEILING | mramber1 | Approved | |
| 11/29/2017 | ELECTRIC - TEMPORARY SERVICE | mramber1 | Approved | |
| 11/29/2017 | ELECTRIC - CONSTRUCTION POWER | mramber1 | Approved | |
| 11/29/2017 | ELECTRIC - PROGRESS | mramber1 | Approved | |
| 11/29/2017 | PLUMBING - ABOVE CEILING | mramber1 | Approved | |
| 11/29/2017 | PLUMBING - PROGRESS | mramber1 | Approved | |
| 11/29/2017 | MECHANICAL - INTERMEDIATE | mramber1 | Approved | |
| 12/01/2017 | FIREWALL/FIREBARRIER/FIRESTOP | mramber1 | Approved | |
| 12/11/2017 | BUILDING - FINAL | mramber1 | Approved | pending all inspections |
| 12/11/2017 | ELECTRIC - FINAL | mramber1 | Approved | addition only |
| 12/11/2017 | CERTIFICATE OF OCCUPANCY | mramber1 | Approved | |
| 12/11/2017 | ELECTRIC - OUTDOOR LIGHTING | mramber1 | Approved | |
| 12/11/2017 | OUTDOOR LIGHTING FINAL | mramber1 | Approved | |
| 12/11/2017 | MECHANICAL - ABOVE CEILING | mramber1 | Approved | |
| 12/14/2017 | MECHANICAL - FINAL | RSHERRY | Approved | FAN COIL FC-3 DOES NOT PROVIDE SUFFICIENT VENTILATION - 150 CFM REQUIRED. CONTACT THE ENGINEER FOR REVIEW OF THE PERFORMANCE OF EF-2 AND EF-3 AND FOR ASSISTANCE WITH FC-3. |
| 12/14/2017 | PLUMBING - FINAL | RSHERRY | Approved | REVIEW OF WATER CHLORINATION REPORT COMPLETE |
| 12/20/2017 | FIRE - FINAL | JPEELDAVIS | Approved | Advised Clayton that TFD has approved the phase 1 and it is ok to occupy |
| 12/20/2017 | ENGINEERING - FINAL | RLEDONNE | Approved | OK FOR TCO FOR PHASE #1. |
| 04/10/2018 | ELECTRIC - UFER | mramber1 | Approved | |
| 04/10/2018 | ELECTRIC - INTERMEDIATE | mramber1 | Approved | |
| 04/10/2018 | PLUMBING - INTERMEDIATE | mramber1 | Approved |