Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ADDITION
Apply Date:
02/01/2017
Applicant:
N/A
Description:
SELF STORAGE
Contractors:
  • A P N BUILDERS INC ,

Permit Reviews

Permit Number - T17CM00838
Permit Status: C of o
Permit Description: SELF STORAGE
Start Date Submittal Complete Date Status  
02/01/2017 PLANS OK TO SUBMIT - COMM 02/13/2017 COMPLETED Review Details
02/13/2017 COMMERCIAL - NEW 03/21/2017 COMPLETED Review Details
03/28/2017 RESUBMITTAL 04/26/2017 COMPLETED Review Details
04/26/2017 RESUBMITTAL 10/25/2017 COMPLETED Review Details
10/25/2017 REVISION - - 1ST 10/25/2017 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T17CM00838
Permit Status: C of o
Permit Description: SELF STORAGE
Total Outstanding Activity Conditions - 1
Date Name
02/01/2017 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T17CM00838
Permit Description: SELF STORAGE
Total Completed Inspections - 36
Date Description Inspector Results Comments
08/09/2017 ELECTRIC - UNDERGROUND BSTEVENS Approved FROM SES EAST TO END OF BLD 2 OK TO COVER
08/15/2017 PLUMBING - ROUGH, SOIL BSTEVENS Approved
08/30/2017 PLUMBING - BACK WATER VALVE AQUIROZ Approved
09/06/2017 BUILDING PRE-SLAB BSTEVENS Approved BUILDING SLAB ONLY
09/11/2017 EXCAVATION/LAYOUT REBAR & ZON BSTEVENS Approved COLUMN FOOTINGS OK TO POUR
09/28/2017 ELECTRIC - INTERMEDIATE NORTH Approved
10/05/2017 PLUMBING - INTERMEDIATE JBURGE Approved ROOF DRAINS, PLUMBING IN WALLS.
10/10/2017 MECHANICAL - ABOVE CEILING JMILITE1 Approved IVRS - Inspection :*
10/10/2017 MECHANICAL - INTERMEDIATE JMILITE1 Approved IVRS - Inspection :*
10/11/2017 FRAMING JMILITE1 Approved OK TO INSULATE AND SHEET ROCK.
10/11/2017 ROOF NAILING JMILITE1 Approved OK TO ROOF.
10/13/2017 PLUMBING - ROOF DRAINS JBURGE Approved
10/19/2017 PLUMBING - YARD WTR LINE/TEST aquiroz Approved Yard water lines for buildings #2, #3, #4, and #5.
11/15/2017 STUCCO MESH DQUINN Approved BUILDING #1 COMPLETELY READY FOR MUD
01/11/2018 SHEET ROCK NAILING ESTEVEN1 Approved APPROVED
03/15/2018 BUILDING ABOVE CEILING JBURGE Approved OK TO SET CEILING TILES.
04/03/2018 PLUMBING - PROGRESS BSTEVENS Approved
04/03/2018 ELECTRIC - PROGRESS BSTEVENS Approved
04/03/2018 ELECTRIC - ABOVE CEILING BSTEVENS Approved
04/03/2018 BUILDING - PROGRESS BSTEVENS Approved
04/03/2018 ELECTRIC - UFER BSTEVENS Approved
04/03/2018 U VALUE FOR WINDOW BSTEVENS Approved
04/03/2018 EXT METAL CLIPS/EXT SHEATHING BSTEVENS Approved
04/03/2018 STEM WALL/RETAINING WALL BSTEVENS Approved
04/09/2018 PLUMBING - SEWER HCS CONNECT ESTEVEN1 Approved REFER TO PERMIT T17CM03989 PRIVATE SEWER
04/09/2018 ELECTRIC - CONSTRUCTION POWER ESTEVEN1 Approved APPROVED
04/11/2018 TEP CLEARANCE - AM ESTEVENS Approved ECO
04/26/2018 MECHANICAL - FINAL JBURGE Approved
04/26/2018 PLUMBING - FINAL JBURGE Approved
04/26/2018 OUTDOOR LIGHTING FINAL JBURGE Approved
04/26/2018 ELECTRIC - OUTDOOR LIGHTING JBURGE Approved
04/26/2018 ELECTRIC - FINAL JBURGE Approved
04/26/2018 BUILDING - FINAL JBURGE Approved PENDING FIRE FINAL
05/04/2018 FIRE - FINAL gsereno1 Approved
05/16/2018 CERTIFICATE OF OCCUPANCY JBURGE Approved
05/17/2018 ENGINEERING - FINAL MRUSSO Approved

Documents

File Name Document Type  
None CERT OF OCC VIEW
INCORRECT ADDRESS.DOC CONSTRPLANS VIEW
001_T1.TIF CONSTRPLANS VIEW
002_1 OF 2.TIF CONSTRPLANS VIEW
003_2 OF 2.TIF CONSTRPLANS VIEW
004_A0.TIF CONSTRPLANS VIEW
005_A1.TIF CONSTRPLANS VIEW
006_A2.TIF CONSTRPLANS VIEW
007_A3.TIF CONSTRPLANS VIEW
008_A4.TIF CONSTRPLANS VIEW
009_A5.TIF CONSTRPLANS VIEW
010_A6.TIF CONSTRPLANS VIEW
011_A7.TIF CONSTRPLANS VIEW
012_A8.TIF CONSTRPLANS VIEW
013_A9.TIF CONSTRPLANS VIEW
014_A10.TIF CONSTRPLANS VIEW
015_A11.TIF CONSTRPLANS VIEW
016_A12.TIF CONSTRPLANS VIEW
017_S1.0.TIF CONSTRPLANS VIEW
018_S1.1.TIF CONSTRPLANS VIEW
019_S1.2.TIF CONSTRPLANS VIEW
020_S1.3.TIF CONSTRPLANS VIEW
021_S1.4.TIF CONSTRPLANS VIEW
022_S1.5.TIF CONSTRPLANS VIEW
023_S1.6.TIF CONSTRPLANS VIEW
024_S2.0.TIF CONSTRPLANS VIEW
025_S2.1.TIF CONSTRPLANS VIEW
026_S2.2.TIF CONSTRPLANS VIEW
027_S2.3.TIF CONSTRPLANS VIEW
028_S2.4.TIF CONSTRPLANS VIEW
029_S2.5.TIF CONSTRPLANS VIEW
030_S2.6.TIF CONSTRPLANS VIEW
031_S3.0.TIF CONSTRPLANS VIEW
032_S4.0.TIF CONSTRPLANS VIEW
033_S4.1.TIF CONSTRPLANS VIEW
034_P1.1.TIF CONSTRPLANS VIEW
035_P1.2.TIF CONSTRPLANS VIEW
036_P1.3.TIF CONSTRPLANS VIEW
037_M1.1.TIF CONSTRPLANS VIEW
038_M1.2.TIF CONSTRPLANS VIEW
039_M1.3.TIF CONSTRPLANS VIEW
040_M1.4.TIF CONSTRPLANS VIEW
041_E0.TIF CONSTRPLANS VIEW
042_E1.TIF CONSTRPLANS VIEW
043_E2.TIF CONSTRPLANS VIEW
044_E3.TIF CONSTRPLANS VIEW
045_E4.TIF CONSTRPLANS VIEW
046_E5.TIF CONSTRPLANS VIEW
047_E6.TIF CONSTRPLANS VIEW
048_E7.TIF CONSTRPLANS VIEW
049_E8.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW