Permit: T17CM00560
Permit Details
Apply Date:
01/23/2017
Applicant:
RICHMOND AMERICAN CONSTRUCTION INC
Description:
SFR RICHT21L16 T16-M0082
Contractors:
- RICHMOND AMERICAN CONSTRUCTION INC
Permit Reviews
Permit Number - T17CM00560
Permit Status: Expired
Permit Description: SFR RICHT21L16 T16-M0082
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/23/2017 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 01/23/2017 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T17CM00560
Permit Status: Expired
Permit Description: SFR RICHT21L16 T16-M0082
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
01/23/2017 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
01/23/2017 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T17CM00560
Permit Description: SFR RICHT21L16 T16-M0082
Total Completed Inspections - 27
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/03/2017 | PLUMBING - SEWER HCS CONNECT | MPUGH1 | Approved | IVRS - Inspection :* |
02/03/2017 | PLUMBING - YARD WTR LINE/TEST | MPUGH1 | Approved | IVRS - Inspection :* |
02/03/2017 | PLUMBING - ROUGH, SOIL | MPUGH1 | Approved | IVRS - Inspection :* |
02/08/2017 | ELECTRIC - UFER | bbenedon | Approved | |
02/08/2017 | EXT METAL CLIPS/EXT SHEATHING | bbenedon | Approved | |
02/08/2017 | BUILDING PRE-SLAB | bbenedon | Approved | |
02/08/2017 | EXCAVATION/LAYOUT REBAR & ZON | bbenedon | Approved | |
02/22/2017 | ROOF NAILING | bbenedon | Approved | |
03/01/2017 | ELECTRIC - CABLE DROP | bbenedon | Approved | |
03/01/2017 | ELECTRIC - CONSTRUCTION POWER | bbenedon | Approved | |
03/02/2017 | TEP CLEARANCE - AM | BBENEDON | Approved | ECO |
03/20/2017 | ELECTRIC - INTERMEDIATE | bbenedon | Approved | |
03/20/2017 | MECHANICAL - INTERMEDIATE | bbenedon | Approved | |
03/20/2017 | U VALUE FOR WINDOW | bbenedon | Approved | |
03/20/2017 | STUCCO MESH | bbenedon | Approved | |
03/21/2017 | PLUMBING - INTERMEDIATE | bbenedon | Approved | |
03/21/2017 | FRAMING | bbenedon | Approved | |
03/28/2017 | PLUMBING - GAS PRESSURE TEST | BBENEDON | Approved | IVRS - Inspection :* |
03/28/2017 | ELECTRIC - UNDERGROUND | BBENEDON | Approved | IVRS - Inspection :* |
03/28/2017 | SHEET ROCK NAILING | BBENEDON | Approved | IVRS - Inspection :* |
05/04/2017 | PLUMBING - PROGRESS | benedon | Approved | |
05/05/2017 | BUILDING - FINAL | bbenedon | Approved | |
05/05/2017 | ELECTRIC - FINAL | bbenedon | Approved | |
05/05/2017 | OUTDOOR LIGHTING FINAL | bbenedon | Approved | |
05/05/2017 | PLUMBING - FINAL | bbenedon | Approved | |
05/05/2017 | MECHANICAL - FINAL | bbenedon | Approved | |
05/05/2017 | GAS CLEARANCE | BBENEDON | Approved |