Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T17CM00478
Permit Details
Apply Date:
01/19/2017
Applicant:
RICHMOND AMERICAN CONSTRUCTION INC
Description:
NEW SFR
Contractors:
- RICHMOND AMERICAN CONSTRUCTION INC
Permit Reviews
Permit Number - T17CM00478
Permit Status: Expired
Permit Description: NEW SFR
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/19/2017 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 01/19/2017 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T17CM00478
Permit Status: Expired
Permit Description: NEW SFR
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
01/19/2017 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
01/19/2017 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T17CM00478
Permit Description: NEW SFR
Total Completed Inspections - 27
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/31/2017 | PLUMBING - SEWER HCS CONNECT | MRAMBER | Approved | IVRS - Inspection :* |
01/31/2017 | PLUMBING - YARD WTR LINE/TEST | MRAMBER | Approved | IVRS - Inspection :* |
01/31/2017 | PLUMBING - ROUGH, SOIL | MRAMBER | Approved | IVRS - Inspection :* |
02/06/2017 | ELECTRIC - UNDERGROUND | bbenedon | Approved | |
02/06/2017 | ELECTRIC - UFER | bbenedon | Approved | |
02/06/2017 | BUILDING PRE-SLAB | bbenedon | Approved | |
02/06/2017 | EXCAVATION/LAYOUT REBAR & ZON | bbenedon | Approved | |
02/17/2017 | ROOF NAILING | BBENEDON | Approved | IVRS - Inspection :* |
02/17/2017 | EXT METAL CLIPS/EXT SHEATHING | BBENEDON | Approved | IVRS - Inspection :* |
03/08/2017 | FRAMING | bbenedon | Approved | |
03/08/2017 | STUCCO MESH | bbenedon | Approved | |
03/08/2017 | U VALUE FOR WINDOW | bbenedon | Approved | |
03/08/2017 | ELECTRIC - INTERMEDIATE | bbenedon | Approved | |
03/08/2017 | ELECTRIC - CABLE DROP | bbenedon | Approved | eco |
03/08/2017 | ELECTRIC - CONSTRUCTION POWER | bbenedon | Approved | |
03/08/2017 | PLUMBING - GAS PRESSURE TEST | bbenedon | Approved | |
03/08/2017 | MECHANICAL - INTERMEDIATE | bbenedon | Approved | |
03/09/2017 | PLUMBING - INTERMEDIATE | bbenedon | Approved | |
03/09/2017 | TEP CLEARANCE - AM | BBENEDON | Approved | ECO |
03/17/2017 | PLUMBING - PROGRESS | bbenedon | Approved | |
03/17/2017 | SHEET ROCK NAILING | bbenedon | Approved | |
04/17/2017 | OUTDOOR LIGHTING FINAL | bbenedon | Approved | |
04/18/2017 | GAS CLEARANCE | BBENEDON | Approved | |
04/19/2017 | MECHANICAL - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
04/19/2017 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
04/19/2017 | ELECTRIC - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
04/19/2017 | BUILDING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |