Permit: T17CM00072
Permit Details
Apply Date:
01/04/2017
Applicant:
RICHMOND AMERICAN CONSTRUCTION INC
Description:
SFR RICHT16L13 T13-M0040
Contractors:
- RICHMOND AMERICAN CONSTRUCTION INC
Permit Reviews
Permit Number - T17CM00072
Permit Status: Expired
Permit Description: SFR RICHT16L13 T13-M0040
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/04/2017 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 01/05/2017 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T17CM00072
Permit Status: Expired
Permit Description: SFR RICHT16L13 T13-M0040
Total Outstanding Activity Conditions - 3
Date | Name |
---|---|
01/04/2017 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
01/04/2017 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
01/04/2017 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T17CM00072
Permit Description: SFR RICHT16L13 T13-M0040
Total Completed Inspections - 26
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/17/2017 | PLUMBING - ROUGH, SOIL | bbenedon | Approved | |
01/17/2017 | PLUMBING - SEWER HCS CONNECT | bbenedon | Approved | |
01/17/2017 | PLUMBING - YARD WTR LINE/TEST | bbenedon | Approved | |
01/20/2017 | ELECTRIC - UNDERGROUND | ESTEVEN1 | Approved | APPROVED |
01/20/2017 | BUILDING PRE-SLAB | ESTEVEN1 | Approved | APPROVED |
01/20/2017 | EXCAVATION/LAYOUT REBAR & ZON | ESTEVEN1 | Approved | APPROVED |
01/31/2017 | ROOF NAILING | MRAMBER | Approved | IVRS - Inspection :* |
01/31/2017 | EXT METAL CLIPS/EXT SHEATHING | MRAMBER | Approved | IVRS - Inspection :* |
02/09/2017 | ELECTRIC - CONSTRUCTION POWER | MPUGH1 | Approved | IVRS - Inspection :* |
02/09/2017 | ELECTRIC - CABLE DROP | MPUGH1 | Approved | IVRS - Inspection :* |
02/13/2017 | TEP CLEARANCE - AM | MPUGH | Approved | TEC |
02/24/2017 | PLUMBING - INTERMEDIATE | bbenedon | Approved | |
02/24/2017 | PLUMBING - GAS PRESSURE TEST | bbenedon | Approved | |
02/24/2017 | U VALUE FOR WINDOW | bbenedon | Approved | |
02/24/2017 | STUCCO MESH | bbenedon | Approved | |
02/27/2017 | MECHANICAL - INTERMEDIATE | ESTEVEN1 | Approved | APPROVED |
02/27/2017 | ELECTRIC - INTERMEDIATE | ESTEVEN1 | Approved | APPROVED |
02/27/2017 | ELECTRIC - UFER | ESTEVEN1 | Approved | APPROVED |
02/27/2017 | FRAMING | ESTEVEN1 | Approved | APPROVED |
03/06/2017 | SHEET ROCK NAILING | ESTEVEN1 | Approved | APPROVED |
04/13/2017 | GAS CLEARANCE | NORTH | Approved | |
04/14/2017 | MECHANICAL - FINAL | JJaworsky | Approved | |
04/14/2017 | OUTDOOR LIGHTING FINAL | JJaworsky | Approved | |
04/14/2017 | ELECTRIC - FINAL | JJaworsky | Approved | |
04/18/2017 | BUILDING - FINAL | mpugh1 | Approved | |
04/18/2017 | PLUMBING - FINAL | mpugh1 | Approved |