Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Withdrwn
Type:
SIGN PERMIT
Address NEW:
3560 N CRAYCROFT RD
Apply Date:
12/15/2016
Applicant:
ADDISIGNS INC *USE THIS ONE*
Description:
signs for new Blake's Lotaburger (later issued per variance case C10-17-05/T17SA00025, under sign permit T17OT00239)

Completed Inspections

Permit Status: Withdrwn
Permit Number: T16OT01481
Permit Description: signs for new Blake's Lotaburger (later issued per variance case C10-17-05/T17SA00025, under sign permit T17OT00239)
Total Completed Inspections - 1
Date Description Inspector Results Comments
12/29/2016 SIGN SITE REVIEW HTHRALL Approved Sign Permit Review
Reviewer: H. Thrall
Date: 12/27/2016
Sign Permit: T16OT01481
Site: 3560 N Craycroft Road, zoned PAD-22
Tenant: Blake's Lotaburger
Sign Code Sections:
3-4 (Application and interpretation of district boundaries)
3-83 (Scenic Corridor District - River & Craycroft are mapped scenic routes)

The following review is for examination of the plans for sufficient data to permit signage (which involves sign type allowance, sign area allowance, dimensional criteria of sign types, etc.) and for potential needed variances or special permits through the Board of Adjustment.
Additional information is required to provide a complete review. Provide dimensioned building elevations T16CM07642, provide dimensioned, city approved development plan sheets 1 &2 DP16-0147.
1) PER 3-83.B.1, DIMENSION BUILDING FRONTAGE. LOT LINE DIMENSION SHOWN. (SHEET 2)
2) PER MAY 21, 2015 SIGN CODE DETERMINATION T15SA00169, DIMENSION EACH BUILDING ELEVATION. ( BUILDING FRONTAGE IS EACH BUILDING ELEVATION). (SHEET 2)
3) PER MAY 21, 2015 SIGN CODE DETERMINATION T15SA00169, PROVIDE SUMMARY OF ALL ATTACHED SIGN AREA -TOTAL PER EACH ELEVATION, NOT TO EXCEED 1.25 SQUARE FEET OF SIGN AREA PER LINEAR FOOT OF BUILDING ELEVATION LENGTH, CANNOT TRANSFER SIGN AREA BETWEEN WALLS, AND NOT TO EXCEED CAP OF 250 SQUARE FEET PER TENANT. (SHEET 2)
4) BE ADVISED - BUILDING PLAN T16CM07642 WAS JUST RESUBMITTED. PAD-22 DESIGN REVIEW COMMITTEE LETTER RECOMMENDS SHADE FOR PATIO, INFERRING PROPOSED CURVE WHERE PLANNED SIGN IS TO BE MOUNTED SHOULD BECOME A SHADE CANOPY. THIS REVIEW IS FOR THE SUBMITTED PLANS ONLY, AND DOES NOT ADDRESS POTENTIAL "CANOPY SIGNAGE"CRITERIA. RESUBMITTAL FOR REVIEW OF CANOPY SIGN CRITERIA IS REQUIRED IF THE CURVE BECOMES A CANOPY. NOTE - VARIANCES WOULD THEN BE REQUIRED BASED UPON ITEMS SEEN THIS REVIEW (SHEET 1)
5) SHEET 1, REVISE TO SHOW SIGN LETTERING MOUNTING TO CURVE STRUCTURE RATHER THAN STANDARD WALL MOUNT AS SHOWN.
6) SHEET 5 & SHEET 6, MENU BOARD ELECTRICAL DIAGRAM STATEMENT CALLS FOR L.E.D. LIGHT SOURCE, DIAGRAM IS STANDARD FLUORESCENT. CLARIFY.
7) ON PAGE 6, ADJUST DETAILS TO REFER FOR SIGN "G" PLEASE.
8) ON PAGE 7, ORDER STATION SHOWS A LOGO, NO HEIGHT DIMENSION - CANNOT EXCEED 7' AND WILL BE TREATED AS MENU BOARD. PROVIDE MOUNTING CLARIFICATION?
9) ON PAGE 7, ORDER STATION IS 10 TALL, THOUGH UNDER 50 SQFT TOTAL AREA, HAS A COVER 5' WIDE - PLEASE CHECK FOOTER SIZE FOR ADEQUACY.
10) ON SHEETS 5-11, ADD NOTATION THAT ALL DETACHED SIGNAGE SHALL BE 1' SETBACK ADJACENT TO VEHICLE USE / DRIVE THRU AREAS (UDC. 7.4.6.F.2.A.2)
11) AS PROPOSED, THE SIGN ON THE CURVE MOUNTED TO THE WEST ELEVATION IS NOT A TYPE OF SIGN IN THE SIGN CODE. A SPECIAL PERMIT THROUGH THE BOARD OF ADJUSTMENT PROCESS FOR AN INTEGRATED ARCHITECTURAL FEATURE IS REQUIRED. (SHEET 1)
12) PER 10/30/15 SIGN CODE DETERMINATION, DIMENSION WIDTH AND HEIGHT OF WALL ABOVE ROOF WHERE "BLAKE'S" SIGNAGE TO BE MOUNTED.


*ADVISEMENT* - FURTHER COMMENTS REGARDING SIGN TYPES, POSSIBLE VARIANCES, AND PERMITTED SIGN AREA MAY BE FORTHCOMING, DEPENDING UPON RESPONSES.