Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Apply Date:
12/23/2016
Applicant:
RAWSON, RHONDA LEE
Description:
SFR
Architects:
  • RAWSON, RHONDA LEE

Permit Reviews

Permit Number - T16CM09601
Permit Status: Final
Permit Description: SFR
Start Date Submittal Complete Date Status  
01/09/2017 RESIDENTIAL - BLDG/WWM 02/06/2017 COMPLETED Review Details
02/22/2017 RESIDENTIAL - BLDG/WWM 08/29/2017 COMPLETED Review Details
12/23/2016 PLANS OK TO SUBMIT - RES 01/09/2017 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T16CM09601
Permit Status: Final
Permit Description: SFR
Total Outstanding Activity Conditions - 1
Date Name
12/23/2016 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T16CM09601
Permit Description: SFR
Total Completed Inspections - 28
Date Description Inspector Results Comments
12/05/2017 EXCAVATION/LAYOUT REBAR & ZON RCAMACHO Approved EXCEPT ENTRY
12/05/2017 ELECTRIC - UFER RCAMACHO Approved
12/13/2017 BUILDING PRE-SLAB RCAMACHO Approved NO WORK
12/13/2017 STEM WALL/RETAINING WALL RCAMACHO Approved PER DETAIL 1/A.2 AND 4/A.2
12/27/2017 PLUMBING - ROUGH, SOIL rbaldwin Approved
12/27/2017 PLUMBING - ROUGH, SOIL mramber1 Approved DWV not on test
04/16/2018 ROOF NAILING RCAMACH1 Approved
04/16/2018 EXT METAL CLIPS/EXT SHEATHING RCAMACH1 Approved
06/28/2018 U VALUE FOR WINDOW RCAMACH1 Approved IVRS - Inspection :*
06/28/2018 STUCCO MESH RCAMACH1 Approved IVRS - Inspection :*
06/29/2018 MECHANICAL - INTERMEDIATE RCAMACH1 Approved IVRS - Inspection :*
07/05/2018 PLUMBING - GAS PRESSURE TEST RCAMACH1 Approved IVRS - Inspection :*
07/05/2018 PLUMBING - INTERMEDIATE RCAMACH1 Approved IVRS - Inspection :*
07/05/2018 ELECTRIC - INTERMEDIATE RCAMACH1 Approved IVRS - Inspection :*
07/05/2018 FRAMING RCAMACH1 Approved IVRS - Inspection :*
08/14/2018 SHEET ROCK NAILING BJONES Approved ADDED SHEET ROCK NAILING INSPECTION
11/09/2018 PLUMBING - YARD WTR LINE/TEST DMCCARTHY Approved plumbing yard water line test
VERY LONG WATER LATERAL
11/21/2018 ELECTRIC - CONSTRUCTION POWER TVALENCIA Approved ECO. OK TO ENERGIZE ELECTRIC NEW CONSTRUCTION
11/23/2018 TEP CLEARANCE - AM DMCCARTHY Approved OK TO ENERGIZE ELECTRIC NEW CONSTRUCTION
ECO
01/18/2019 ELECTRIC - CABLE DROP MHASSAN Approved approved upon 2090 approval from MHASSAN
01/18/2019 ELECTRIC - UNDERGROUND MHASSAN Approved approved upon 2090 approval from MHASSAN
01/18/2019 MECHANICAL - FINAL MHASSAN Approved
01/18/2019 ELECTRIC - FINAL MHASSAN Approved
01/31/2019 PLUMBING - PROGRESS RCAMACHO Approved approved upon 3090 approval from RCAMACHO
01/31/2019 SEPTIC - SYSTEM RCAMACHO Approved approved upon 3090 approval from RCAMACHO
01/31/2019 PLUMBING - FINAL RCAMACHO Approved
02/05/2019 OUTDOOR LIGHTING FINAL MHASSAN Approved
02/05/2019 BUILDING - FINAL MHASSAN Approved fix stairwell railing as it needs inch and a half hand clearance all the way around it

Documents

File Name Document Type  
001_CVR.TIF CONSTRPLANS VIEW
002_A-1.TIF CONSTRPLANS VIEW
003_A-1A.TIF CONSTRPLANS VIEW
004_A-2.TIF CONSTRPLANS VIEW
005_A-3.TIF CONSTRPLANS VIEW
006_A-4.TIF CONSTRPLANS VIEW
007_A-6.TIF CONSTRPLANS VIEW
008_A-6.TIF CONSTRPLANS VIEW
009_E-1.TIF CONSTRPLANS VIEW
010_E-2.TIF CONSTRPLANS VIEW
011_M-1.TIF CONSTRPLANS VIEW
012_M-2.TIF CONSTRPLANS VIEW
013_P-1.TIF CONSTRPLANS VIEW
014_P-2.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW
HVAC LOAD CALCS.PDF DOCUMENTS VIEW
None DOCUMENTS VIEW