Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
3423 E FLOWER ST #03
Apply Date:
12/19/2016
Applicant:
D R CONSTRUCTION SERVICES LLC
Description:
REPL GAS LINE
Contractors:
  • D R CONSTRUCTION SERVICES LLC

Permit Reviews

Permit Number - T16CM09443
Permit Status: Final
Permit Description: REPL GAS LINE
Start Date Submittal Complete Date Status  
12/19/2016 WALK THRU - COMM 12/19/2016 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T16CM09443
Permit Status: Final
Permit Description: REPL GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
12/19/2016 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T16CM09443
Permit Description: REPL GAS LINE
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/30/2016 PLUMBING - FINAL TVALENC1 Approved
12/30/2016 PLUMBING - GAS PRESSURE TEST TVALENC1 Approved 1- SHALL PROVIDE A CARBON MONOXCIDE DETECTOR.
2- SHALL BOND THE GAS LINE.
3- SHALL SEAL THE GAS LINE PENETRATION THRU THE EXTERIOR MASONARY WALL.
4- SHALL EXTEND AND TERMINATE THE WATER HEATER T & P DRAIN TO THE DRIP PAN.
5- SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT ON THE WATER HEATER VENT CONNECTOR AND DRAFT COLLAR.
6OKAY TO BACKFILL TRENCH.
7- PROVIDE A GAS SHUT OFF VALVE FOR THE RANGE.
01/06/2017 GAS CLEARANCE TVALENCIA Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW