Permit: T16CM09442
Permit Details
Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
3423 E FLOWER ST #08
Address NEW:
3423 E FLOWER ST #08
Apply Date:
12/19/2016
Applicant:
D R CONSTRUCTION SERVICES LLC
Description:
REPL GAS LINE
Contractors:
- D R CONSTRUCTION SERVICES LLC
Permit Reviews
Permit Number - T16CM09442
Permit Status: Final
Permit Description: REPL GAS LINE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/19/2016 | WALK THRU - COMM | 12/19/2016 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T16CM09442
Permit Status: Final
Permit Description: REPL GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/19/2016 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T16CM09442
Permit Description: REPL GAS LINE
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/30/2016 | PLUMBING - FINAL | TVALENC1 | Approved | |
| 12/30/2016 | PLUMBING - GAS PRESSURE TEST | TVALENC1 | Approved | 1- SHALL PROVIDE A CARBON MONOXCIDE DETECTOR. 2- SHALL BOND THE GAS LINE. 3- SHALL SEAL THE GAS LINE PENETRATION THRU THE EXTERIOR MASONARY WALL. 4- SHALL EXTEND AND TERMINATE THE WATER HEATER T & P DRAIN TO THE DRIP PAN. 5- SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT ON THE WATER HEATER VENT CONNECTOR AND DRAFT COLLAR. 6OKAY TO BACKFILL TRENCH. 7- PROVIDE A GAS SHUT OFF VALVE FOR THE RANGE. |
| 01/06/2017 | GAS CLEARANCE | TVALENCIA | Approved |