Permit: T16CM09150
Permit Details
Status:
Expired
Type:
SINGLE FAMILY NEW
Address:
5033 S RIVER RUN DR
Address NEW:
5033 S RIVER RUN DR
Apply Date:
12/07/2016
Applicant:
K B HOME OF TUCSON *APA*
Description:
SFR OAK1740 T16-M0015
Contractors:
- K B HOME OF TUCSON *APA*
Permit Reviews
Permit Number - T16CM09150
Permit Status: Expired
Permit Description: SFR OAK1740 T16-M0015
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/07/2016 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 12/07/2016 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T16CM09150
Permit Status: Expired
Permit Description: SFR OAK1740 T16-M0015
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 12/07/2016 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 12/07/2016 | SPECIAL INSPECTION IS REQUIRED FOR EARTHWORK |
Completed Inspections
Permit Status: Expired
Permit Number: T16CM09150
Permit Description: SFR OAK1740 T16-M0015
Total Completed Inspections - 28
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2016 | PLUMBING - SEWER HCS CONNECT | MPUGH1 | Approved | IVRS - Inspection :* |
| 12/23/2016 | PLUMBING - YARD WTR LINE/TEST | MPUGH1 | Approved | IVRS - Inspection :* |
| 12/23/2016 | PLUMBING - ROUGH, SOIL | MPUGH1 | Approved | IVRS - Inspection :* |
| 12/29/2016 | ROOF NAILING | MRAMBER | Approved | IVRS - Inspection :* |
| 12/29/2016 | EXT METAL CLIPS/EXT SHEATHING | MRAMBER | Approved | IVRS - Inspection :* |
| 12/30/2016 | ELECTRIC - UFER | ESTEVEN1 | Approved | MISSING UFER |
| 12/30/2016 | ELECTRIC - UNDERGROUND | ESTEVEN1 | Approved | APPROVED |
| 12/30/2016 | BUILDING PRE-SLAB | ESTEVEN1 | Approved | APPROVED |
| 12/30/2016 | EXCAVATION/LAYOUT REBAR & ZON | ESTEVEN1 | Approved | APPROVED |
| 02/22/2017 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
| 02/22/2017 | PLUMBING - GAS PRESSURE TEST | MRAMBER | Approved | IVRS - Inspection :* |
| 02/22/2017 | ELECTRIC - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
| 02/22/2017 | FRAMING | MRAMBER | Approved | IVRS - Inspection :* |
| 03/03/2017 | U VALUE FOR WINDOW | RCAMACHO | Approved | |
| 03/03/2017 | STUCCO MESH | RCAMACHO | Approved | |
| 03/08/2017 | ELECTRIC - CABLE DROP | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/08/2017 | ELECTRIC - CONSTRUCTION POWER | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/09/2017 | TEP CLEARANCE - AM | CAMACHO | Approved | ECO |
| 03/22/2017 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/23/2017 | SHEET ROCK NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
| 04/11/2017 | PLUMBING - GAS PRESS TEST FNL | RCAMACHO | Approved | IVRS - Inspection :* |
| 04/12/2017 | GAS CLEARANCE | CAMACHO | Approved | |
| 04/26/2017 | PLUMBING - PRE SLAB | mramber1 | Approved | |
| 04/26/2017 | SITE - SEWER | mramber1 | Approved | |
| 04/26/2017 | MECHANICAL - FINAL | mramber1 | Approved | |
| 04/28/2017 | PLUMBING - FINAL | RCAMACHO | Approved | |
| 04/28/2017 | ELECTRIC - FINAL | RCAMACHO | Approved | |
| 04/28/2017 | BUILDING - FINAL | RCAMACHO | Approved |