Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T16CM08792
Permit Details
Apply Date:
11/22/2016
Applicant:
LENNAR ARIZONA CONSTRUCTION INC
Description:
SFR LENN4062 T16-M0067
Contractors:
- LENNAR ARIZONA CONSTRUCTION INC
Permit Reviews
Permit Number - T16CM08792
Permit Status: Final
Permit Description: SFR LENN4062 T16-M0067
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
11/22/2016 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 11/22/2016 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T16CM08792
Permit Status: Final
Permit Description: SFR LENN4062 T16-M0067
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
11/22/2016 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T16CM08792
Permit Description: SFR LENN4062 T16-M0067
Total Completed Inspections - 26
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/18/2017 | PLUMBING - SEWER HCS CONNECT | TVALENC1 | Approved | IVRS - Inspection :* |
01/18/2017 | PLUMBING - ROUGH, SOIL | TVALENC1 | Approved | IVRS - Inspection :* |
01/23/2017 | BUILDING PRE-SLAB | ESTEVEN1 | Approved | PLUMBING IS NOT WRAPPED. |
01/23/2017 | ELECTRIC - UFER | ESTEVEN1 | Approved | APPROVED |
01/23/2017 | ELECTRIC - UNDERGROUND | ESTEVEN1 | Approved | APPROVED |
01/24/2017 | EXCAVATION/LAYOUT REBAR & ZON | MPUGH1 | Approved | IVRS - Inspection :* |
02/01/2017 | PLUMBING - YARD WTR LINE/TEST | ESTEVEN1 | Approved | APPROVED |
02/16/2017 | ROOF NAILING | ESTEVEN1 | Approved | APPROVED |
02/16/2017 | EXT METAL CLIPS/EXT SHEATHING | ESTEVEN1 | Approved | APPROVED |
03/07/2017 | ELECTRIC - CONSTRUCTION POWER | TVALENC1 | Approved | |
03/07/2017 | ELECTRIC - CABLE DROP | TVALENC1 | Approved | |
03/08/2017 | TEP CLEARANCE - AM | TVALENCIA | Approved | ECO |
03/27/2017 | MECHANICAL - INTERMEDIATE | TVALENC1 | Approved | |
03/27/2017 | PLUMBING - GAS PRESSURE TEST | TVALENC1 | Approved | |
03/27/2017 | PLUMBING - INTERMEDIATE | TVALENC1 | Approved | |
03/27/2017 | ELECTRIC - INTERMEDIATE | TVALENC1 | Approved | |
03/27/2017 | U VALUE FOR WINDOW | TVALENC1 | Approved | |
03/27/2017 | STUCCO MESH | TVALENC1 | Approved | |
03/27/2017 | FRAMING | TVALENC1 | Approved | |
04/04/2017 | SHEET ROCK NAILING | TVALENC1 | Approved | |
11/17/2017 | MECHANICAL - FINAL | TVALENC1 | Approved | IVRS - Inspection :* |
11/17/2017 | PLUMBING - PROGRESS | TVALENC1 | Approved | IVRS - Inspection :* |
11/17/2017 | OUTDOOR LIGHTING FINAL | TVALENC1 | Approved | IVRS - Inspection :* |
11/20/2017 | PLUMBING - FINAL | TVALENC1 | Approved | IVRS - Inspection :* |
11/20/2017 | ELECTRIC - FINAL | TVALENC1 | Approved | IVRS - Inspection :* |
11/20/2017 | BUILDING - FINAL | TVALENC1 | Approved | IVRS - Inspection :* |