Permit Details

Status:
Expired
Type:
COMMERCIAL ADDITION
Apply Date:
11/14/2016
Applicant:
BRECKENRIDGE, KLINDT DUNCAN
Description:
INTERIOR RENOVATION AND ADDITION
Architects:
  • BRECKENRIDGE, KLINDT DUNCAN
Contractors:
  • SELLERS AND SONS INC

Permit Reviews

Permit Number - T16CM08557
Permit Status: Expired
Permit Description: INTERIOR RENOVATION AND ADDITION
Start Date Submittal Complete Date Status  
01/25/2017 3RD PARTY REVIEW - COMMERCIAL 03/02/2017 COMPLETED Review Details
11/14/2016 PLANS OK TO SUBMIT - COMM 01/25/2017 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T16CM08557
Permit Status: Expired
Permit Description: INTERIOR RENOVATION AND ADDITION
Total Outstanding Activity Conditions - 5
Date Name
11/14/2016 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
02/22/2017 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
02/22/2017 SPECIAL INSPECTION FOR STRUCTURAL WELDING IS REQUIRED.
02/22/2017 SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED.
02/22/2017 SPECIAL INSPECTION IS REQUIRED FOR POST INSTALLED ANCHORS.

Completed Inspections

Permit Status: Expired
Permit Number: T16CM08557
Permit Description: INTERIOR RENOVATION AND ADDITION
Total Completed Inspections - 30
Date Description Inspector Results Comments
03/17/2017 EXCAVATION/LAYOUT REBAR & ZON JMILITE1 Approved OK TO POUR CONTROL ROOM FOOTINGS AND WATER TANK SLAB.
03/22/2017 STEM WALL/RETAINING WALL ESTEVEN1 Approved APPROVED
03/24/2017 PLUMBING - ROUGH, SOIL JMILITE1 Approved OK TO POUR SLAB AND FOOTING AT SERVER ROOM.
OK TO COVER ELEC. AND POUR SLAB AT NEW CONTROL ROOM.
OK TO POUR SLAB AT RESTROOMS.
OK TO COVER ELEC. TRENCH AT CU 1&2.
OK TO BACKFILL DWV AT DRINKING FOUNTAIN.
03/27/2017 BUILDING PRE-SLAB ESTEVEN1 Approved APPROVED
04/28/2017 ROOF NAILING BSTEVENS Approved
05/23/2017 FRAMING BSTEVENS Approved OK TO CLOSE WALLS
05/25/2017 REINFORCED MASONRY PRE-GROUT BSTEVENS Approved
06/07/2017 BUILDING - PROGRESS BSTEVENS Approved
06/07/2017 ELECTRIC - SERVICE UPGRADE BSTEVENS Approved
06/08/2017 TEP CLEARANCE - AM BSTEVENS Approved INCR
07/26/2017 MECHANICAL - PROGRESS BSTEVENS Approved
07/26/2017 MECHANICAL - ABOVE CEILING BSTEVENS Approved
07/26/2017 PLUMBING - PROGRESS BSTEVENS Approved
07/26/2017 ELECTRIC - PROGRESS BSTEVENS Approved
07/26/2017 SHEET ROCK NAILING BSTEVENS Approved
07/26/2017 BUILDING ABOVE CEILING BSTEVENS Approved
07/26/2017 PLUMBING - YARD WTR LINE/TEST BSTEVENS Approved
07/26/2017 PLUMBING - INTERMEDIATE BSTEVENS Approved
07/26/2017 ELECTRIC - UNDERGROUND BSTEVENS Approved
08/22/2017 FIRE - FINAL jdonovan Approved
08/22/2017 RIGHT OF WAY - FINAL DR Approved
08/22/2017 ELECTRIC - FINAL BSTEVENS Approved
08/22/2017 PLUMBING - FINAL BSTEVENS Approved
08/22/2017 MECHANICAL - FINAL BSTEVENS Approved
08/22/2017 MECHANICAL - INTERMEDIATE BSTEVENS Approved
08/22/2017 BUILDING - FINAL BSTEVENS Approved
08/23/2017 NPPO - FINAL MRUSSO Approved
08/23/2017 SIGN - FINAL MRUSSO Approved
08/23/2017 LANDSCAPE - FINAL MRUSSO Approved
08/23/2017 ENGINEERING - FINAL MRUSSO Approved