Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T16CM07978
Permit Details
Apply Date:
10/20/2016
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
RESTAURANT
Architects:
- DAVID EFAW
Contractors:
- D.G. FENN CONSTRUCTION INC
Permit Reviews
Permit Number - T16CM07978
Permit Status: C of o
Permit Description: RESTAURANT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/24/2017 | RESUBMITTAL | 02/16/2017 | COMPLETED |
02/16/2017 | RESUBMITTAL | 05/03/2017 | COMPLETED |
05/16/2017 | REVISION - - 1ST | 05/17/2017 | COMPLETED |
05/17/2017 | REVISION - - 1ST | 05/18/2017 | COMPLETED |
09/19/2017 | REVISION - - 2ND | 09/19/2017 | COMPLETED |
09/19/2017 | REVISION - - 2ND | 10/02/2017 | COMPLETED |
10/20/2016 | PLANS OK TO SUBMIT - COMM | 10/20/2016 | COMPLETED |
10/20/2016 | COMMERCIAL - NEW | 12/16/2016 | COMPLETED |
12/16/2016 | RESUBMITTAL | 01/24/2017 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T16CM07978
Permit Status: C of o
Permit Description: RESTAURANT
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/20/2016 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T16CM07978
Permit Description: RESTAURANT
Total Completed Inspections - 47
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/07/2017 | SITE - SEWER | RCAMACHO | Approved | |
06/07/2017 | ELECTRIC - UFER | RCAMACHO | Approved | |
06/21/2017 | PLUMBING - ROUGH, SOIL | RCAMACHO | Approved | |
06/29/2017 | PLUMBING - PRE SLAB | RCAMACHO | Approved | |
07/19/2017 | ELECTRIC - UNDERGROUND | RCAMACHO | Approved | |
08/10/2017 | ROOF NAILING | RCAMACHO | Approved | |
08/11/2017 | EXT METAL CLIPS/EXT SHEATHING | BBENEDO1 | Approved | IVRS - Inspection :* |
08/22/2017 | STUCCO MESH | RCAMACHO | Approved | |
08/25/2017 | PLUMBING - ROOF DRAINS | RCAMACHO | Approved | |
08/25/2017 | FRAMING | RCAMACHO | Approved | |
09/01/2017 | PLUMBING - GAS PRESSURE TEST | RCAMACHO | Approved | |
09/11/2017 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | |
09/11/2017 | EXCAVATION/LAYOUT REBAR & ZON | RCAMACHO | Approved | SEE RFI |
09/19/2017 | SHEET ROCK NAILING | rcamacho | Approved | |
09/27/2017 | ELECTRIC - ABOVE CEILING | RCAMACHO | Approved | |
09/27/2017 | MECHANICAL - HOODS | RCAMACHO | Approved | |
09/28/2017 | BUILDING - PROGRESS | RCAMACHO | Approved | |
09/29/2017 | ELECTRIC - CONSTRUCTION POWER | RCAMACHO | Approved | ECO |
10/02/2017 | TEP CLEARANCE - AM | CAMACHO | Approved | ECO |
10/10/2017 | ELECTRIC - PROGRESS | RCAMACHO | Approved | |
10/12/2017 | PLUMBING - GAS PRESS TEST FNL | RCAMACHO | Approved | OK TO CLEAR GAS |
10/13/2017 | GAS CLEARANCE | CAMACHO | Approved | |
10/25/2017 | NPPO - FINAL | RLEDONNE | Approved | |
10/25/2017 | SIGN - FINAL | RLEDONNE | Approved | |
10/25/2017 | LANDSCAPE - FINAL | RLEDONNE | Approved | |
10/25/2017 | ENGINEERING - FINAL | RLEDONNE | Approved | |
10/27/2017 | FIRE - FINAL | jvincent | Approved | final approved. will do the following. -will mount exitinguishers -will add decal over front door. -will call us back to place key in lock box -still need co2 final. |
10/27/2017 | FIRE - KITCHEN EXH HOOD FINAL | jvincent | Approved | approved per CB. see hood permit. |
10/27/2017 | PLUMBING - PROGRESS | mramber1 | Approved | |
10/27/2017 | MECHANICAL - PROGRESS | mramber1 | Approved | |
10/30/2017 | STEM WALL/RETAINING WALL | RCAMACHO | Approved | |
10/30/2017 | BUILDING ABOVE CEILING | RCAMACHO | Approved | |
10/30/2017 | U VALUE FOR WINDOW | RCAMACHO | Approved | |
10/31/2017 | MECHANICAL - HOOD SYSTEMS | RCAMACHO | Approved | |
10/31/2017 | MECHANICAL - ABOVE CEILING | RCAMACHO | Approved | |
10/31/2017 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | |
10/31/2017 | BUILDING PRE-SLAB | RCAMACHO | Approved | |
10/31/2017 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | |
10/31/2017 | ELECTRIC - FINAL | RCAMACHO | Approved | |
10/31/2017 | ELECTRIC - OUTDOOR LIGHTING | RCAMACHO | Approved | |
11/01/2017 | REINFORCED MASONRY PRE-GROUT | RCAMACHO | Approved | |
11/06/2017 | RIGHT OF WAY - FINAL | AP | Approved | |
11/06/2017 | PLUMBING - YARD WTR LINE/TEST | RCAMACHO | Approved | |
11/06/2017 | PLUMBING - ABOVE CEILING | RCAMACHO | Approved | |
11/06/2017 | BUILDING - FINAL | RSHERRY | Approved | ALL REPORTS SUBMITTED |
11/06/2017 | MECHANICAL - FINAL | RSHERRY | Approved | REVIEW OF AIR BALANCE REPORT COMPLETE |
11/06/2017 | PLUMBING - FINAL | RSHERRY | Approved | REVIEW OF WATER CHLORINATION REPORT COMPLETE |