Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
9850 E 1ST ST
Address NEW:
9850 E 1ST ST
Apply Date:
09/14/2016
Applicant:
RAM PLUMBING ***APA***
Description:
REPLACE WATER HEATER
Contractors:
  • RAM PLUMBING ***APA***

Outstanding Activity Conditions

Permit Number - T16CM07114
Permit Status: Expired
Permit Description: REPLACE WATER HEATER
Total Outstanding Activity Conditions - 1
Date Name
09/14/2016 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T16CM07114
Permite Description: REPLACE WATER HEATER
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/20/2016 PLUMBING - FINAL N/A Partial Approval DO NOT USE FLEX TUBING TO PIPE T&P DRAIN.
PROVIDE A 20 AMP DEDICATED CIRCUIT. NO CORD AND PLUG ALLOWED. PROVIDE A DISCONNECT OR A LOCKING TYPE BREAKER.
EXTEND T&P DISCHARGE COMPLETELY OUT OF WALL INTO PLANTER.

Documents

File Name Document Type  
None DOCUMENTS VIEW