Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address NEW:
1137 E HEDRICK DR 1
Apply Date:
08/31/2016
Applicant:
THERESA M RIESS
Description:
NEW SFR

Permit Reviews

Permit Number - T16CM06716
Permit Status: Final
Permit Description: NEW SFR
Start Date Submittal Complete Date Status  
08/31/2016 RESIDENTIAL - BLDG/ZONING/ENGINE/WWM 11/10/2016 COMPLETED Review Details
11/10/2016 RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO 12/09/2016 COMPLETED Review Details
12/22/2016 RESUBMITTAL 01/30/2017 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T16CM06716
Permit Status: Final
Permit Description: NEW SFR
Total Outstanding Activity Conditions - 1
Date Name
08/31/2016 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T16CM06716
Permit Description: NEW SFR
Total Completed Inspections - 28
Date Description Inspector Results Comments
12/23/2016 FLOODPLAIN INSP PB Approved The use a portion of the FEMA Special Flood Hazard Area Zone AE per the Flood Insurance Rate Maps 04019C1689L, specifically described as:

A portion of Parcel 113-08-199D; Catalina Poultry Acres Unit No 4, E 61.43' Lot 40

For the purpose of constructing an elevated Main House and a Guest House.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

This floodplain use permit is issued with the following 9 conditions:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the buildings, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from construction of the Main House or the Guest House within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.

2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

3) For purposes of this permit the following flood elevations shall be used for the Main House and the Guest House:
Base Flood Elevation (BFE) = 2372.1 feet NAVD 1988
Regulatory Flood Elevation (RFE) = 2373.1 feet NAVD 1988
The Main House and the Guest House are to have lowest finished floor elevated at or above the Regulatory Flood Elevation (RFE) and lowest point of any attached appliances is to be at or above the Regulatory Flood Elevation (RFE).

4) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the finished construction or Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the Main House and the Guest House, if applicable, as well as the identity and location of all other equipment/machinery servicing the Main House and the Guest House. A separate elevation certificate for each structure is required.

5) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the pouring of the slabs or Intermediate Inspection (P2I). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the Main House and the Guest House, if applicable, as well as the identity and location of all other equipment/machinery servicing the Main House and the Guest House. A separate elevation certificate for each structure is required.

6) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T16OT01077 FOR INFORMATION PLEASE CALL 791-5550."

7) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.

8) All work shall conform to the approved site plan, T16CM06716, which is made part of this permit.

9) This permit is specific to the improvements for 1137 E Hedrick Drive as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.


This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.
12/23/2016 FLOODPLAIN INSP PB Approved The use a portion of the FEMA Special Flood Hazard Area Zone AE per the Flood Insurance Rate Maps 04019C1689L, specifically described as:

A portion of Parcel 113-08-199D; Catalina Poultry Acres Unit No 4, E 61.43' Lot 40

For the purpose of constructing an elevated Main House and a Guest House.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

This floodplain use permit is issued with the following 9 conditions:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the buildings, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from construction of the Main House or the Guest House within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.

2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

3) For purposes of this permit the following flood elevations shall be used for the Main House and the Guest House:
Base Flood Elevation (BFE) = 2372.1 feet NAVD 1988
Regulatory Flood Elevation (RFE) = 2373.1 feet NAVD 1988
The Main House and the Guest House are to have lowest finished floor elevated at or above the Regulatory Flood Elevation (RFE) and lowest point of any attached appliances is to be at or above the Regulatory Flood Elevation (RFE).

4) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the finished construction or Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the Main House and the Guest House, if applicable, as well as the identity and location of all other equipment/machinery servicing the Main House and the Guest House. A separate elevation certificate for each structure is required.

5) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the pouring of the slabs or Intermediate Inspection (P2I). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the Main House and the Guest House, if applicable, as well as the identity and location of all other equipment/machinery servicing the Main House and the Guest House. A separate elevation certificate for each structure is required.

6) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T16OT01077 FOR INFORMATION PLEASE CALL 791-5550."

7) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.

8) All work shall conform to the approved site plan, T16CM06716, which is made part of this permit.

9) This permit is specific to the improvements for 1137 E Hedrick Drive as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.


This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.
02/23/2017 EXCAVATION/LAYOUT REBAR & ZON BSTEVENS Approved
03/10/2017 PLUMBING - ROUGH, SOIL JMILITE1 Approved OK TO BACKFILL DWV.
03/10/2017 STEM WALL/RETAINING WALL JMILITE1 Approved OK TO GROUT STEM WALL.
03/23/2017 BUILDING PRE-SLAB ESTEVEN1 Approved APPROVED
05/04/2017 REINFORCED MASONRY PRE-GROUT BSTEVENS Approved
06/08/2017 ROOF NAILING DQUINN Approved
08/16/2017 PLUMBING - YARD WTR LINE/TEST JMILITE1 Approved OK TO BACKFILL YARD WATER.
UFER PROVIDED. NO NEED FOR GROUND RODS.
09/14/2017 PLUMBING - GAS PRESSURE TEST ESTEVEN1 Approved APPROVED
09/14/2017 PLUMBING - SEWER HCS CONNECT ESTEVEN1 Approved APPROVED
09/14/2017 PLUMBING - INTERMEDIATE ESTEVEN1 Approved APPROVED
09/15/2017 GAS CLEARANCE ESTEVENS Approved
09/19/2017 ELECTRIC - UNDERGROUND ESTEVEN1 Approved APPROVED. POWER COMING IN
09/22/2017 PLUMBING - PROGRESS DQUINN Approved WEST SIDE PVC DRAINS OK TO BACKFILL
11/17/2017 U VALUE FOR WINDOW DQUINN Approved
11/17/2017 ELECTRIC - UFER DQUINN Approved
11/17/2017 ELECTRIC - INTERMEDIATE DQUINN Approved
11/17/2017 ELECTRIC - CABLE DROP DQUINN Approved
11/17/2017 ELECTRIC - CONSTRUCTION POWER DQUINN Approved
11/17/2017 MECHANICAL - INTERMEDIATE DQUINN Approved
11/17/2017 FRAMING DQUINN Approved
11/20/2017 TEP CLEARANCE - AM DQUINN Approved ECO
04/10/2018 OUTDOOR LIGHTING FINAL BSTEVENS Approved
06/08/2018 MECHANICAL - FINAL bbenedo1 Approved
06/08/2018 PLUMBING - FINAL bbenedo1 Approved
06/08/2018 ELECTRIC - FINAL bbenedo1 Approved
12/21/2018 BUILDING - FINAL BGRANT1 Approved PER L.MAKUS IN ENGINEERING T16OT1077 FUP EL CERT IS IN SIRE. THIS 1090 CAN BE FINALED

Documents

File Name Document Type  
001_SITE PLAN.TIF CONSTRPLANS VIEW
002_FLOOR PLAN _MAIN HOUSE.TIF CONSTRPLANS VIEW
003_FLOOR PLAN / ELEVATION_LITTLE HOUSE.TIF CONSTRPLANS VIEW
004_ELEVATIONS_MAIN HOUSE.TIF CONSTRPLANS VIEW
005_SECTIONS.TIF CONSTRPLANS VIEW
006_FOUNDATION.TIF CONSTRPLANS VIEW
007_FRAMING.TIF CONSTRPLANS VIEW
008_DETAILS.TIF CONSTRPLANS VIEW
009_PLUMBING / DRAINAGE / WATER / GAS.TIF CONSTRPLANS VIEW
010_PLUMBING / DRAINAGE / WATER_LITTLE HOUSE.TIF CONSTRPLANS VIEW
011_ELECTRICAL_MAIN HOUSE.TIF CONSTRPLANS VIEW
012_ELECTRICAL / MECHANICAL_LITTLE HOUSE.TIF CONSTRPLANS VIEW
013_MECHANICAL_MAIN HOUSE.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW