Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T16CM02685
Permit Details
Apply Date:
04/12/2016
Applicant:
PULTE HOME CORP AZ *APA*
Description:
SFR PULT40198 T14-M0033
Contractors:
- PULTE HOME CORP AZ *APA*
Permit Reviews
Permit Number - T16CM02685
Permit Status: Expired
Permit Description: SFR PULT40198 T14-M0033
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/12/2016 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 04/13/2016 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T16CM02685
Permit Status: Expired
Permit Description: SFR PULT40198 T14-M0033
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
04/12/2016 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
04/12/2016 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T16CM02685
Permite Description: SFR PULT40198 T14-M0033
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/22/2016 | BUILDING - FINAL | N/A | Partial Approval | IVRS - Inspection :* Provide all 3rd party reports. |
Completed Inspections
Permit Status: Expired
Permit Number: T16CM02685
Permit Description: SFR PULT40198 T14-M0033
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/20/2016 | PLUMBING - ROUGH, SOIL | TVALENC1 | Approved | dwv water test provided, hcs cnnection okay, tracer wire provided, yard water line from meter to house service okay tracer wire providedIVRS - Inspection :* |
05/20/2016 | PLUMBING - SEWER HCS CONNECT | TVALENC1 | Approved | IVRS - Inspection :* |
05/20/2016 | PLUMBING - YARD WTR LINE/TEST | TVALENC1 | Approved | IVRS - Inspection :* |
05/26/2016 | BUILDING PRE-SLAB | TVALENC1 | Approved | IVRS - Inspection :* |
05/26/2016 | EXCAVATION/LAYOUT REBAR & ZON | TVALENC1 | Approved | IVRS - Inspection :* |
06/17/2016 | ROOF NAILING | TValenc1 | Approved | |
06/17/2016 | EXT METAL CLIPS/EXT SHEATHING | TValenc1 | Approved | |
07/05/2016 | FRAMING | rico | Approved | |
07/07/2016 | ELECTRIC - TEMPORARY SERVICE | MPUGH1 | Approved | IVRS - Inspection :* |
07/07/2016 | ELECTRIC - CABLE DROP | MPUGH1 | Approved | IVRS - Inspection :* |
07/13/2016 | SHEET ROCK NAILING | MPUGH1 | Approved | IVRS - Inspection :* |
08/22/2016 | MECHANICAL - FINAL | MPUGH1 | Approved | IVRS - Inspection :* |
08/22/2016 | MECHANICAL - INTERMEDIATE | MPUGH1 | Approved | IVRS - Inspection :* |
08/22/2016 | PLUMBING - FINAL | MPUGH1 | Approved | IVRS - Inspection :* |
08/22/2016 | PLUMBING - GAS PRESS TEST FNL | MPUGH1 | Approved | IVRS - Inspection :* |
08/22/2016 | PLUMBING - GAS PRESSURE TEST | MPUGH1 | Approved | IVRS - Inspection :* |
08/22/2016 | PLUMBING - INTERMEDIATE | MPUGH1 | Approved | IVRS - Inspection :* |
08/22/2016 | OUTDOOR LIGHTING FINAL | MPUGH1 | Approved | IVRS - Inspection :* |
08/22/2016 | ELECTRIC - FINAL | MPUGH1 | Approved | IVRS - Inspection :* |
08/22/2016 | ELECTRIC - INTERMEDIATE | MPUGH1 | Approved | IVRS - Inspection :* |
08/22/2016 | ELECTRIC - UFER | MPUGH1 | Approved | IVRS - Inspection :* |
08/22/2016 | U VALUE FOR WINDOW | MPUGH1 | Approved | IVRS - Inspection :* |
08/22/2016 | STUCCO MESH | MPUGH1 | Approved | IVRS - Inspection :* |