Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T16CM02173
Permit Details
Apply Date:
03/23/2016
Applicant:
MERITAGE HOMES
Description:
SFR PLAN1610 T16-M0011
Contractors:
- MERITAGE HOMES
- MERITAGE HOMES CONSTRUCTION INC *** APA***
Permit Reviews
Permit Number - T16CM02173
Permit Status: Final
Permit Description: SFR PLAN1610 T16-M0011
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/23/2016 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 03/24/2016 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T16CM02173
Permit Status: Final
Permit Description: SFR PLAN1610 T16-M0011
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
03/23/2016 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T16CM02173
Permit Description: SFR PLAN1610 T16-M0011
Total Completed Inspections - 25
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/21/2016 | PLUMBING - YARD WTR LINE/TEST | TVALENC1 | Approved | IVRS - Inspection :* |
04/26/2016 | PLUMBING - PRE SLAB | MPUGH1 | Approved | IVRS - Inspection :* |
04/26/2016 | ELECTRIC - UNDERGROUND | MPUGH1 | Approved | IVRS - Inspection :* |
04/26/2016 | BUILDING PRE-SLAB | MPUGH1 | Approved | IVRS - Inspection :* |
04/26/2016 | EXCAVATION/LAYOUT REBAR & ZON | MPUGH1 | Approved | IVRS - Inspection :* |
05/09/2016 | ROOF NAILING | TVALENC1 | Approved | IVRS - Inspection :* |
05/09/2016 | EXT METAL CLIPS/EXT SHEATHING | TVALENC1 | Approved | IVRS - Inspection :* |
05/18/2016 | ELECTRIC - CABLE DROP | MPUGH1 | Approved | IVRS - Inspection :* |
06/02/2016 | MECHANICAL - INTERMEDIATE | TVALENC1 | Approved | IVRS - Inspection :* |
06/02/2016 | PLUMBING - GAS PRESSURE TEST | TVALENC1 | Approved | IVRS - Inspection :* |
06/02/2016 | PLUMBING - INTERMEDIATE | TVALENC1 | Approved | IVRS - Inspection :* |
06/02/2016 | ELECTRIC - INTERMEDIATE | TVALENC1 | Approved | IVRS - Inspection :* |
06/02/2016 | U VALUE FOR WINDOW | TVALENC1 | Approved | IVRS - Inspection :* |
06/02/2016 | STUCCO MESH | TVALENC1 | Approved | IVRS - Inspection :* |
06/02/2016 | FRAMING | TVALENC1 | Approved | IVRS - Inspection :* |
06/03/2016 | SITE - SEWER | MPUGH1 | Approved | IVRS - Inspection :* |
06/03/2016 | PLUMBING - SEWER HCS CONNECT | MPUGH1 | Approved | IVRS - Inspection :* |
06/14/2016 | SHEET ROCK NAILING | MPUGH1 | Approved | IVRS - Inspection :* |
08/01/2016 | PLUMBING - ROUGH, SOIL | MPUGH | Approved | |
08/01/2016 | ELECTRIC - UFER | MPUGH | Approved | |
08/01/2016 | MECHANICAL - FINAL | MPUGH1 | Approved | IVRS - Inspection :* |
08/01/2016 | PLUMBING - FINAL | MPUGH1 | Approved | IVRS - Inspection :* |
08/01/2016 | PLUMBING - GAS PRESS TEST FNL | MPUGH1 | Approved | IVRS - Inspection :* |
08/01/2016 | ELECTRIC - FINAL | MPUGH1 | Approved | IVRS - Inspection :* |
08/01/2016 | BUILDING - FINAL | MPUGH1 | Approved | IVRS - Inspection :* |