Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
300 S TOOLE AV
Apply Date:
02/09/2016
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
INDOOR RACETRACK
Architects:
  • CHRIS HARKINS CULBERTSON
Contractors:
  • CALDWELL CONSTRUCTION L L C *C*

Permit Reviews

Permit Number - T16CM00934
Permit Status: C of o
Permit Description: INDOOR RACETRACK
Start Date Submittal Complete Date Status  
02/09/2016 PLANS OK TO SUBMIT - COMM 02/09/2016 COMPLETED Review Details
02/16/2016 3RD PARTY REVIEW - COMMERCIAL 03/16/2016 COMPLETED Review Details
03/16/2016 POST 3RD PARTY REVIEW 03/24/2016 COMPLETED Review Details
03/24/2016 RESUBMITTAL 04/04/2016 COMPLETED Review Details
07/07/2016 3RD PARTY REVIEW - REVISION/OTHER 07/07/2016 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T16CM00934
Permit Status: C of o
Permit Description: INDOOR RACETRACK
Total Outstanding Activity Conditions - 1
Date Name
02/09/2016 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T16CM00934
Permit Description: INDOOR RACETRACK
Total Completed Inspections - 18
Date Description Inspector Results Comments
04/14/2016 PLUMBING - ROUGH, SOIL ESTEVEN1 Approved IVRS - Inspection :*
04/29/2016 PLUMBING - ABOVE CEILING ESTEVEN1 Approved IVRS - Inspection :*
04/29/2016 PLUMBING - INTERMEDIATE ESTEVEN1 Approved IVRS - Inspection :*
05/05/2016 FRAMING ESTEVEN Approved APPROVED
05/05/2016 SHEET ROCK NAILING ESTEVEN Approved APPROVED
06/06/2016 ELECTRIC - INTERMEDIATE ESTEVEN1 Approved APPROVED
06/06/2016 MECHANICAL - ABOVE CEILING ESTEVEN1 Approved IVRS - Inspection :*
06/06/2016 MECHANICAL - INTERMEDIATE ESTEVEN1 Approved IVRS - Inspection :*
06/06/2016 ELECTRIC - ABOVE CEILING ESTEVEN1 Approved IVRS - Inspection :*
06/06/2016 BUILDING ABOVE CEILING ESTEVEN1 Approved IVRS - Inspection :*
06/17/2016 MECHANICAL - FINAL ESTEVEN1 Approved IVRS - Inspection :*
06/17/2016 PLUMBING - FINAL ESTEVEN1 Approved IVRS - Inspection :*
06/17/2016 ELECTRIC - FINAL ESTEVEN1 Approved IVRS - Inspection :*
06/17/2016 FIRE SPKLR - FINAL CBASALDUA Approved
06/21/2016 FIRE - ALARM FINAL CBASALDUA Approved
07/08/2016 ZONING - FINAL DROBERTS Approved
07/08/2016 BUILDING - FINAL ESTEVEN1 Approved IVRS - Inspection :*
07/12/2016 FIRE - FINAL CBASALDUA Approved

Documents

File Name Document Type  
None CERT OF OCC VIEW
001_COVER.TIF CONSTRPLANS VIEW
002_A0.1.TIF CONSTRPLANS VIEW
003_A0.5.TIF CONSTRPLANS VIEW
004_A1.0.TIF CONSTRPLANS VIEW
005_A1.1.TIF CONSTRPLANS VIEW
006_A1.2.TIF CONSTRPLANS VIEW
007_A2.0.TIF CONSTRPLANS VIEW
002_C-1.TIF CONSTRPLANS VIEW
008_M1.1.TIF CONSTRPLANS VIEW
009_M1.2.TIF CONSTRPLANS VIEW
010_M1.3.TIF CONSTRPLANS VIEW
011_M1.4.TIF CONSTRPLANS VIEW
012_M2.1.TIF CONSTRPLANS VIEW
013_M3.1.TIF CONSTRPLANS VIEW
014_P1.1.TIF CONSTRPLANS VIEW
015_P1.2.TIF CONSTRPLANS VIEW
016_P2.1.TIF CONSTRPLANS VIEW
017_E0.1.TIF CONSTRPLANS VIEW
018_E0.2.TIF CONSTRPLANS VIEW
019_E0.3.TIF CONSTRPLANS VIEW
020_E0.4.TIF CONSTRPLANS VIEW
021_E1.1.TIF CONSTRPLANS VIEW
022_E1.4.TIF CONSTRPLANS VIEW
023_E2.1.TIF CONSTRPLANS VIEW
024_E2.2.TIF CONSTRPLANS VIEW
025_E2.3.TIF CONSTRPLANS VIEW
026_E2.4.TIF CONSTRPLANS VIEW
027_E2.5.TIF CONSTRPLANS VIEW
028_E3.1.TIF CONSTRPLANS VIEW
029_E4.1.TIF CONSTRPLANS VIEW
030_E5.1.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW
None DOCUMENTS VIEW