Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SIGN PERMIT
Apply Date:
07/28/2015
Applicant:
FLUORESCO SERVICES LLC/ EVERBRITE LLC *APA*
Description:
3- ILLUM MENU BOARDS / EMC PANELS CHANGES TWICE PER DAY

Completed Inspections

Permit Status: Final
Permit Number: T15OT00980
Permit Description: 3- ILLUM MENU BOARDS / EMC PANELS CHANGES TWICE PER DAY
Total Completed Inspections - 5
Date Description Inspector Results Comments
08/05/2015 SIGN SITE REVIEW ACONNOR Approved
08/05/2015 SIGN SITE REVIEW BWIESE Approved MCDONALDS
T15OT00980
REVSION: NA/ORGINAL
RECEIVED: 7/27/15
REVIEWED: 8/4/15 by Sign Permit Team
Question #1. Are you removing the existing Menu Board currently on site?

APPLICATION & DRAWING DENIED. A revision is required as per Sign Code 3-16.
Revisions required include:

1.Application:
a.Frontage is listed at 45 ft. (3 X 45'= 135 sq.ft. of sign area allowed). Current site already has 286' sq.ft. This would mean it is already over its sign allowance and would not be allowed any more signs. Heather has calculated that the correct numbers to enter in the frontage box are 61' & 160' (as per approved site plan DP15-0068)
b.Leave SIGNS B, C & E off the application. They are incidental signs less than 2 sq feet. The drawing have been reviewed by COT structural.

2.Drawings:
*Page 1:
All of the information on the application that pertains to SIGN (A)
must also be on Page 1 (A) of the drawing.
The information required on Page 1 (A) of the drawing includes
1.A written description of SIGN (A)
2.A scaled image of SIGN (A) showing its
a.Cabinet width & length in "decimal feet" (ex. 3.58')
b.the square footage in "decimal feet" (ex. 24.17 SQ FT)
c.the scale used (ex. SCALE 3/8"=1')
d.The caisson and its width & length in "decimal feet"
e.Side view of entre sign, pole cover , support pole and caisson,
f.Top View required ( because this sign face rotates)
g.OAH (over all height of sign)
3.A construction/electrical diagram of SIGN (A) showing
a.Construction details
b.Attachment details (number, size and type of anchors/bolts)
c.Type of illumination (ex. LED)
d.Show & indicate the DISCONNECT SWITCH
e.Indicate the AMPS__ VOLTS__ CIRCUITS__
f.Include the following note " 24 Hour programmable times installed
to comply with the COT outdoor lighting code"
g.Because this sign has a rotating face the page must be labeled as a EMC
h.Indicate the method by which the sign face rotation occurs & how often.
4.Each page must show
a. Name of contractor applying for the permit (ex. Fluoresco)
b.Must note page number and number of pages submitted. (ex. Page 1 of 10)
*Page 2:
All of the information on the application that pertains to SIGN (B)
must also be on Page 2 (B) of the drawing.
The information required on Page 2 (B) of the drawing includes
1.A written description of SIGN (B)
2.A scaled image of SIGN (B) showing its
a.width & length in "decimal feet" (ex. 3.58') of main support structure.
b.The caisson and its width & length in "decimal feet"
c.Side view of entre sign, pole cover , support pole and caisson,
d.Top View required
e.OAH (over all height of sign)
f.Include the following note " Structural Review Only"
g.Include the following note " Incidental sign under 2 sq. ft."
3.A construction diagram of SIGN (B) showing
a.Construction details
b.Attachment details (number, size and type of anchors/bolts)
c.If this sign has any illumination, then electrical details must be included on this page.
4.Each page must show
a. Name of contractor applying for the permit (ex. Fluoresco)
b.Must note page number and number of pages submitted. (ex. Page 2 of 10)
*Page 3:
All of the information on the application that pertains to SIGN (C)
must also be on Page 3 (C) of the drawing.
The information required on Page 3 (C) of the drawing includes
1.A written description of SIGN (C)
2.A scaled image of SIGN (C) showing its
a.width & length in "decimal feet" (ex. 3.58') of main support structure.
b.The caisson and its width & length in "decimal feet"
c.Side view of entre sign, pole cover , support pole and caisson,
d.Top View required
e.OAH (over all height of sign)
f.Include the following note " Structural Review Only"
3.A construction diagram of SIGN (C) showing
a.Construction details
b.Attachment details (number, size and type of anchors/bolts)
c.Type of illumination (ex. LED)
d.Show & indicate the DISCONNECT SWITCH
e.Indicate the AMPS__ VOLTS__ CIRCUITS__
f.Include the following note " 24 Hour programmable times installed
to comply with the COT outdoor lighting code"
4.Each page must show
a. Name of contractor applying for the permit (ex. Fluoresco)
b.Must note page number and number of pages submitted. (ex. Page 3 of 10)
*Page 4:
All of the information on the application that pertains to SIGN (D)
must also be on Page 4 (D) of the drawing.
The information required on Page 4 (D) of the drawing includes
1.A written description of SIGN (D)
2.A scaled image of SIGN (D) showing its
a.Cabinet width & length in "decimal feet" (ex. 3.58')
b.the square footage in "decimal feet" (ex. 24.17 SQ FT)
c.the scale used (ex. SCALE 3/8"=1')
d.The caisson and its width & length in "decimal feet"
e.Side view of entre sign, pole cover , support pole and caisson,
f.Top View required ( because this sign face rotates)
g.OAH (over all height of sign)
3.A construction/electrical diagram of SIGN (D) showing
a.Construction details
b.Attachment details (number, size and type of anchors/bolts)
c.Type of illumination (ex. LED)
d.Show & indicate the DISCONNECT SWITCH
e.Indicate the AMPS__ VOLTS__ CIRCUITS__
f.Include the following note " 24 Hour programmable times installed
to comply with the COT outdoor lighting code"
g.Because this sign has a rotating face the page must be labeled as a EMC
h.Include the following note " Timer controlled movement shows & calls out frequency & mechanism of movement."
*Page 5:
All notes for Page 3(C) apply to Page 5(E)
*Page 6:
All notes for Page 4(D) apply to Page 6(F)
*Page 7:
Site Plan:
a.The document used for the site plan is not a stamped and approved COT drawing from the development package.
b.The small print on the original drawing is unreadable in this scanned reduction.
c. Include the following note "In Drive Thru: One (1) foot setback from face of curb to leading edge of sign."
Technical drawing: Everbrite DWG. NO. IN449731S
a."Order Here" is shown on drawing yet is not on SIGNS C & E?
b. Remove "Order Here" from Everbrite DWG. NO. IN449731S


Subject to receipt of corrected plans, additional comments may be forth coming.
10/16/2015 SIGN EXCAVATION ACONNOR Approved Excavation inspection was conducted on permit T15CM05666
11/10/2015 SIGN INSPECTION DROBERTS Approved
11/10/2015 SIGN ELECTRIC DROBERTS Approved