Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
5530 E 2ND ST
Apply Date:
12/09/2015
Applicant:
CAPITAL CONSTRUCTION L L C ,
Description:
ADULT CARE HOME
Contractors:
  • CAPITAL CONSTRUCTION L L C
  • CAPITAL CONSTRUCTION L L C ,

Permit Reviews

Permit Number - T15CM08647
Permit Status: C of o
Permit Description: ADULT CARE HOME
Start Date Submittal Complete Date Status  
12/09/2015 RESIDENTIAL - BLDG/ZONING-WALKTHRU 12/14/2015 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T15CM08647
Permit Status: C of o
Permit Description: ADULT CARE HOME
Total Outstanding Activity Conditions - 1
Date Name
12/09/2015 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T15CM08647
Permit Description: ADULT CARE HOME
Total Completed Inspections - 25
Date Description Inspector Results Comments
12/18/2015 PLUMBING - ROUGH, SOIL JBURGE Approved IVRS - Inspection :*
12/22/2015 ELECTRIC - UFER JBURGE Approved IVRS - Inspection :*
12/22/2015 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
12/22/2015 EXCAVATION/LAYOUT REBAR & ZON JBURGE Approved IVRS - Inspection :*
01/13/2016 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*
01/13/2016 ROOF NAILING JBURGE Approved IVRS - Inspection :*
01/13/2016 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
01/21/2016 MECHANICAL - INTERMEDIATE JBURGE Approved IVRS - Inspection :*
01/21/2016 PLUMBING - INTERMEDIATE JBURGE Approved IVRS - Inspection :*
01/21/2016 ELECTRIC - TEMPORARY SERVICE JBURGE Approved IVRS - Inspection :*
01/21/2016 ELECTRIC - INTERMEDIATE JBURGE Approved IVRS - Inspection :*
01/21/2016 STUCCO MESH JBURGE Approved IVRS - Inspection :*
01/21/2016 FRAMING JBURGE Approved IVRS - Inspection :*
01/28/2016 PLUMBING - SEWER HCS CONNECT JBURGE Approved IVRS - Inspection :*
02/01/2016 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
02/04/2016 FIREWALL/FIREBARRIER/FIRESTOP JBURGE Approved IVRS - Inspection :*
02/16/2016 ELECTRIC - CABLE DROP JBURGE Approved IVRS - Inspection :*
02/19/2016 PLUMBING - YARD WTR LINE/TEST JBURGE Approved IVRS - Inspection :*
03/22/2016 FIRE - FINAL CCLARK Approved
03/22/2016 BUILDING - PROGRESS JBURGE Approved IVRS - Inspection :*
03/22/2016 MECHANICAL - FINAL JBURGE Approved IVRS - Inspection :*
03/22/2016 PLUMBING - FINAL JBURGE Approved IVRS - Inspection :*
03/22/2016 OUTDOOR LIGHTING FINAL JBURGE Approved IVRS - Inspection :*
03/22/2016 ELECTRIC - FINAL JBURGE Approved IVRS - Inspection :*
03/22/2016 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*

Documents

File Name Document Type  
None CERT OF OCC VIEW
001_T1.1.TIF CONSTRPLANS VIEW
002_L2.1.TIF CONSTRPLANS VIEW
003_A1.1.TIF CONSTRPLANS VIEW
004_A2.1.TIF CONSTRPLANS VIEW
005_A3.1.TIF CONSTRPLANS VIEW
006_A4.1.TIF CONSTRPLANS VIEW
007_S1.0.TIF CONSTRPLANS VIEW
008_S2.0.TIF CONSTRPLANS VIEW
009_S3.0.TIF CONSTRPLANS VIEW
010_M1.1.TIF CONSTRPLANS VIEW
011_P1.1.TIF CONSTRPLANS VIEW
013_P2.1.TIF CONSTRPLANS VIEW
014_E1.1.TIF CONSTRPLANS VIEW
015_S2.1.TIF CONSTRPLANS VIEW
016_F1.1.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW